PowerConnect B-DCX4S Backbone Hardware Reference Manual
23
53-1001808-01
Customizing a chassis name
3
Customizing a chassis name
For FOS 6.2.0 and later, the chassis name of the PowerConnect B-DCX-4S can be up to 15
characters long; can include alpha, numeric, and underscore characters; and must begin with an
alpha character.
1. Type chassisName followed by the new name in double quotes.
switch:admin>
chassisname
"DCX4S_chassis_1"
Committing configuration...
Done.
2. Record the new name for reference.
switch:admin>
chassisname
DCX4S_chassis_1
3. Record the new name for reference.
Setting the domain ID
Each switch in the fabric must have a unique domain ID. The domain ID can be manually set
through the configure command or can be automatically set. The default domain ID for the
PowerConnect B-DCX-4S is “1”. Use the fabricShow command to view the already assigned domain
IDs.
1. Enter switchDisable to disable the PowerConnect B-DCX-4S.
2. Enter configure.
3. Enter y at the “Fabric parameters” prompt:
Fabric parameters (yes, y, no, n): [no]
y
4. Enter a unique domain ID:
Domain: (1.239) [1]
3
5. Complete the remaining prompts or press Ctrl+D to accept the settings and exit.
6. Enter switchEnable to re-enable the PowerConnect B-DCX-4S.
Setting the date and time
The date and time settings are used for logging events. Switch operation does not depend on the
date and time; a switch with an incorrect date and time value still functions properly. However,
because the date and time are used for logging, error detection, and troubleshooting, they should
be set correctly.
Содержание PowerConnect B-DCX-4S Backbone
Страница 8: ...viii PowerConnect B DCX 4S Backbone Hardware Reference Manual 53 1001808 01 ...
Страница 24: ...10 PowerConnect B DCX 4S Backbone Hardware Reference Manual 53 1001808 01 Network manageability 1 ...
Страница 113: ...PowerConnect B DCX 4S Backbone Hardware Reference Manual 99 53 1001808 01 Environmental regulation compliance A ...
Страница 114: ...100 PowerConnect B DCX 4S Backbone Hardware Reference Manual 53 1001808 01 Environmental regulation compliance A ...
Страница 134: ...120 PowerConnect B DCX4S Backbone Hardware Reference Manual 53 1001808 01 ...