About Your System
33
Thermal sensor
not detected
on
x.
A memory module without a
thermal sensor is installed in
the specified memory slot.
Replace the memory
module. See "System
Memory" on page 76.
Time-of-day
clock stopped.
Faulty battery or faulty chip. See "Troubleshooting the
System Battery" on page 126.
Time-of-day not
set - please run
SETUP program.
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 39. If the problem
persists, replace the system
battery. See "System Battery"
on page 100.
Timer chip
counter 2 failed.
Faulty system board.
See "Getting Help" on
page 149.
TPM
configuration
operation
honored. System
will now reset.
A TPM configuration
command has been entered.
The system reboots and
executes the command.
Information only.
TPM
configuration
operation is
pending. Press
(I) to Ignore
OR (M) to Modify
to allow this
change and reset
the system.
WARNING:
Modifying could
prevent
security.
This message displays during
system restart after a TPM
configuration command has
been entered. User
interaction is required to
proceed.
Enter I or M to proceed.
TPM failure
A Trusted Platform Module
(TPM) function has failed.
See "Getting Help" on
page 149.
Message
Causes
Corrective Actions
book.book Page 33 Friday, January 6, 2012 2:11 PM
Содержание DR4000 Restore Manager
Страница 1: ...Dell DR4000 Systems Owner s Manual Regulatory Model E13S Series Regulatory Type E13S001 ...
Страница 10: ...10 Contents ...
Страница 120: ...120 Installing System Components ...
Страница 138: ...138 Troubleshooting Your System ...
Страница 142: ...142 Running the System Diagnostics ...
Страница 148: ...148 Jumpers and Connectors ...
Страница 150: ...150 Getting Help ...
Страница 156: ...156 Index ...