DD9500 and DD9800 with ERSO
For a DD9500 and DD9800 system with ERSO:
String
(Loop)
I/O - Port
Shelf Port
Length
1
I/O 6 - Port 0 A controller port 0 of shelf V1.1
2M
1
I/O 2 - Port 1 B controller port 0 of the highest number shelf in V1
2M
2
I/O 3 - Port 0 A controller port 0 of shelf V2.1
2M
2
I/O 2 - Port 0 B controller port 0 of the highest number shelf in V2
2M
3
I/O 9 - Port 2 A controller port 0 of shelf V3.1
2M
3
I/O 3 - Port 1 B controller port 0 of the highest number shelf in V3
5M
4
I/O 2 - Port 2 A controller port 0 of shelf V4.1
5M
4
I/O 3 - Port 2 B controller port 0 of the highest number shelf in V4
5M
5
I/O 2 - Port 3 A controller port 0 of shelf V5.1
5M
5
I/O 9 - Port 0 B controller port 0 of the highest number shelf in V5
5M
6
I/O 9 - Port 3 A controller port 0 of shelf V6.1
5M
6
I/O 6 - Port 1 B controller port 0 of the highest number shelf in V6
5M
7
I/O 6 - Port 2 A controller port 0 of shelf V7.1
5M
7
I/O 9 - Port 1 B controller port 0 of the highest number shelf in V7
5M
8
I/O 6 - Port 3 A controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
8
I/O 3 - Port 3 B controller HOST port of the SSD shelf or DD
Cloud Tier metadata shelf
2M
a. Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Connect Cables and Power on
80
Data Domain DD9500 and DD9800 Systems
6.1
Hardware Overview and Installation Guide
Содержание Data Domain DD9500
Страница 6: ...FIGURES 6 Data Domain DD9500 and DD9800 Systems 6 1 Hardware Overview and Installation Guide ...
Страница 8: ...TABLES 8 Data Domain DD9500 and DD9800 Systems 6 1 Hardware Overview and Installation Guide ...
Страница 10: ...Revision history 10 Data Domain DD9500 and DD9800 Systems 6 1 Hardware Overview and Installation Guide ...
Страница 36: ...Hardware Overview 36 Data Domain DD9500 and DD9800 Systems 6 1 Hardware Overview and Installation Guide ...