l
Each component is intended to operate with all working power supplies installed.
l
Provide a suitable power source with electrical overload protection.
l
A safe electrical earth connection must be provided to each power cord. Check
the grounding of the power sources before applying power.
l
The plug on each power supply cord is used as the main device to disconnect
power from the system. Ensure that the socket outlets are located near the
equipment and are easily accessible.
l
Permanently unplug the unit if you think it is damaged in any way and before
moving the system. A DD9500/DD9800 system includes four power supplies. To
completely remove system power, you must disconnect all four power supplies.
l
The power connections must always be disconnected prior to removal or
replacement of a power supply module from any of the components in the system.
l
A faulty power supply module must be replaced within 24 hours.
l
Do not lift system components by yourself. A DD9500/DD9800 system weighs up
to 117 lbs (53.2 kg), an ES30 expansion shelf weighs up to 68 lbs (30.8 kg), and a
DS60 shelf weighs up to 225 lbs (90.7 kg).
CAUTION
Data Domain systems are heavy. Use at least two people or a mechanical lift
to move any system.
l
Do not lift an expansion shelf by the handles on any modules. The handles are not
designed to support the weight of the populated shelf.
l
To comply with applicable safety, emission, and thermal requirements, covers
must not be removed and all bays must be fitted with plug-in modules.
l
Once removed from the shipping box, it is ok to lift the DD9500/DD9800 system
or the chassis with the four handles to place in a rack. You will need to remove the
handles from the sides before sliding the system in the rack. The four handles
should be saved for later use.
Figure 1 Warning about lifting the system
l
Load the rack with storage shelves beginning at the bottom and the DD9500
system in the designated location to prevent the rack from becoming top-heavy.
l
For ESD protection, Data Domain recommends that you wear a suitable antistatic
wrist or ankle strap. Observe all conventional ESD precautions when handling
plug-in modules and components.
Planning and Site Preparation
Safety information
13
Содержание Data Domain DD9500
Страница 6: ...FIGURES 6 Data Domain DD9500 and DD9800 Systems 6 1 Hardware Overview and Installation Guide ...
Страница 8: ...TABLES 8 Data Domain DD9500 and DD9800 Systems 6 1 Hardware Overview and Installation Guide ...
Страница 10: ...Revision history 10 Data Domain DD9500 and DD9800 Systems 6 1 Hardware Overview and Installation Guide ...
Страница 36: ...Hardware Overview 36 Data Domain DD9500 and DD9800 Systems 6 1 Hardware Overview and Installation Guide ...