BigIron RX Installation Guide
81
53-1001811-01
Verifying proper operation
2
TABLE 13
Desired and abnormal LED states after system power on
LED
Desired state
Meaning
Abnormal
state
Meaning or action
Management module
Active
The Active LED on
one of the installed
management
modules should be
on.
The module is
functioning as the
active management
module.
Off
Neither of the management
modules is managing the switch
fabric and interface modules.
A problem could have occurred
during initialization. Check your
attached PC or terminal for
possible error messages.
Pwr
On
The module is
receiving power.
Off
The module is not receiving power.
You can do the following:
•
Make certain that the
module is installed properly.
For more information, refer to
“Installing BigIron RX-4
modules”
on page 33,
“Installing BigIron RX-8
modules”
on page 42,
“Installing BigIron RX-16
modules”
on page 52, or
“Installing BigIron RX-32
modules”
on page 62.
•
If using AC power supplies,
see the entry for the AC
power supply LED in this
table for more information.
10/100/1000
Ethernet Port
On (Green)
A link is established
with the remote port.
Off
A link is not established with the
remote port. You can do the
following:
•
Verify that the connection to
the other device has been
properly made. Also, make
certain that the other device
is powered on and operating
correctly.
•
Try using a different cable.
10/100/1000
Ethernet Port
On or blinking
(Yellow)
The port is
transmitting and
receiving packets.
Off for an
extended
period
The port is not transmitting or
receiving packets.
You can check the other
10/100/1000 Ethernet port LED
to make sure a link is established
with the remote port. If not, take
the actions described in the
Meaning or Action column for the
other 10/100/1000 Ethernet port
LED.
Содержание BigIron RX-16
Страница 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Страница 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Страница 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Страница 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Страница 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Страница 239: ...BigIron RX Installation Guide 227 53 1001811 01 Internet drafts C The TACACS Protocol version 1 78 ...