BigIron RX Installation Guide
125
53-1001811-01
Managing the interface modules
5
To disable the automatic check and synchronization during bootup, enter the following command at
the global CONFIG level:
BigIron RX(config)# lp disable-lp-sync-check
Syntax: lp disable-lp-sync-check
Provided that you save this configuration by entering the write memory command, the system will
disable the automatic check and synchronization of the IronWare images starting with the next
software reload or system reset and each reload or reset after that.
To re-enable the automatic check and synchronization of the IronWare images during bootup, enter
the following command at the global CONFIG level:
BigIron RX(config)# no lp disable-lp-sync-check
Syntax: no lp disable-lp-sync-check
Changing the boot source
By default, the interface modules boot from the primary IronWare image located in the interface
modules’ flash memory. If desired, you can change the boot source of one or all interface modules
to one of the following sources:
•
Management module
•
PCMCIA flash card in slot 1 or 2
•
Primary or secondary IronWare image in the management module’s flash memory
•
Interface module
•
Secondary IronWare image in interface module’s flash memory
•
TFTP server
You can also specify an interactive boot, which allows you to enter a separate command after the
interface module comes up. The command specifies the source from which one or all interface
modules should boot.
When changing the boot source for one or all interface modules, you can specify one of the
following:
•
An immediate boot for one interface module from a specified source.
•
An automatic boot for one or all interface modules from a specified source starting with the
next software reload or system reset and each reload or reset after that.
The CLI command for specifying an immediate boot for one interface module is the same as that
for specifying an automatic boot for one or all modules. The only difference is the CLI level from
which you specify the command. You must specify the command for an immediate boot in the
Privileged EXEC level and the command for an automatic boot in the global CONFIG level.
The following sections explain how to specify an immediate boot and an automatic boot.
Specifying an immediate boot
You can specify an immediate boot for one interface module from a specified source by entering
the lp boot system command in the Privileged EXEC level. The entered command will override the
default or configured boot source one time only.
Содержание BigIron RX-16
Страница 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Страница 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Страница 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Страница 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Страница 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Страница 239: ...BigIron RX Installation Guide 227 53 1001811 01 Internet drafts C The TACACS Protocol version 1 78 ...
Страница 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...