Scheduling a system reload
7
To disable the automatic check and synchronization during bootup, enter the following command at
the global CONFIG level:
BigIron RX(config)# lp disable-lp-sync-check
Syntax: lp disable-lp-sync-check
Provided that you save this configuration by entering the write memory command, the system will
disable the automatic check and synchronization of the IronWare images starting with the next
software reload or system reset and each reload or reset after that.
To re-enable the automatic check and synchronization of the IronWare images during bootup, enter
the following command at the global CONFIG level:
BigIron RX(config)# no lp disable-lp-sync-check
Syntax: no lp disable-lp-sync-check
Scheduling a system reload
In addition to reloading the BigIron RX Series system manually, you can configure the system to
reload itself at a specific time or after a specific amount of time has passed.
NOTE
The scheduled reload feature requires the system clock. You can use a Simple Network Time
Protocol (SNTP) server to set the clock or you can set the device clock manually.
Reloading at a specific time
To schedule a system reload for a specific time, use one of the following methods.
To schedule a system reload from the primary flash module for 6:00:00 AM, January 19, 2004,
enter the following command at the Privileged EXEC level of the CLI:
BigIron RX# reload at 06:00:00 01-19-04
Syntax: reload at <hh:mm:ss> <mm-dd-yy> [primary | secondary]
<hh:mm:ss> is the hours, minutes, and seconds.
<mm-dd-yy> is the month, day, and year.
primary | secondary specifies whether the reload is to occur from the primary code flash module or
the secondary code flash module. The default is primary.
Reloading after a specific amount of time
To schedule a system reload to occur after a specific amount of time has passed on the system
clock, use one of the following methods.
To schedule a system reload from the secondary flash one day and 12 hours later, enter the
following command at the Privileged EXEC level of the CLI:
BigIron RX# reload after 01:12:00 secondary
Syntax: reload after <dd:hh:mm> [primary | secondary]
Содержание BigIron RX-16
Страница 12: ...xii BigIron RX Installation Guide 53 1001811 01 ...
Страница 36: ...24 BigIron RX Installation Guide 53 1001811 01 Supported software features 1 ...
Страница 100: ...88 BigIron RX Installation Guide 53 1001811 01 Verifying proper operation 2 ...
Страница 110: ...98 BigIron RX Installation Guide 53 1001811 01 RJ 45 procedures 3 ...
Страница 148: ...136 BigIron RX Installation Guide 53 1001811 01 Removing MAC address entries 5 ...
Страница 239: ...BigIron RX Installation Guide 227 53 1001811 01 Internet drafts C The TACACS Protocol version 1 78 ...
Страница 240: ...228 BigIron RX Installation Guide 53 1001811 01 Internet drafts C ...