Figure 109. AC PSU status indicator
1. AC PSU handle
2. Socket
3. Release latch
Table 29. AC PSU status indicator codes
Power indicator codes
Condition
Green
Indicates that a valid power source is connected to the PSU
and the PSU is operational.
Blinking amber
Indicates an issue with the PSU.
Not powered on
Indicates that the power is not connected to the PSU.
Blinking green
Indicates that the firmware of the PSU is being updated.
CAUTION:
Do not disconnect the power cord or
unplug the PSU when updating firmware. If firmware
update is interrupted, the PSUs will not function.
Blinking green and powers off
When hot-plugging a PSU, it blinks green five times at a rate
of 4 Hz and powers off. This indicates a PSU mismatch due to
efficiency, feature set, health status, or supported voltage.
CAUTION:
If two PSUs are installed, both the PSUs
must have the same type of label; for example,
Extended Power Performance (EPP) label. Mixing
PSUs from previous generations of PowerEdge
servers is not supported, even if the PSUs have the
same power rating. This results in a PSU mismatch
condition or failure to power on the system.
CAUTION:
If two PSUs are used, they must be of
the same type and have the same maximum output
power.
CAUTION:
When correcting a PSU mismatch, replace
the PSU with the blinking indicator. Swapping the
PSU to make a matched pair can result in an error
condition and an unexpected system shutdown. To
change from a high output configuration to a low
output configuration or vice versa, you must power
off the system.
CAUTION:
AC PSUs support both 240 V and 120 V
input voltages with the exception of Titanium PSUs,
which support only 240 V. When two identical PSUs
receive different input voltages, they can output
different wattages, and trigger a mismatch.
122
System diagnostics and indicator codes