47
The SCSI backplane functional blocks include the following:
•
Ultra320 LVD SCSI bus passes SCSI signals between the SCSI drives and the main board
A standard 68-pin SCSI connector provides the SCSI connection from the main board to
the SCSI backplane.
Two 80-pin (SCA-2 blind-mate) connectors are located on the SCSI backplane board to
mate with hot-swap LVD SCSI drives in the drive bay.
•
Fault Tolerant Enclosure Management
SAF-TE
SCSI power control
LED control logic
•
Server management
I
2
C interface
I
2
C Serial CMOS EEPROM (FRU)
Temperature sensor
QLogic* GEM359* SCSI Hot-swap Controller
The QLogic GEM359 Hot-swap Controller resides on the SCSI backplane board. The primary
functions of the GEM359 are as follows:
•
Implements the SAF-TE command set
•
Controls the SCSI hard drive fault LEDs
•
Provides a path for management information via the SCSI
•
Retrieves hard drive fault status, SCSI backplane temperature, and fan failure information via
the IPMB
•
Queries the status of the power distribution board by retrieving information from the BMC via
the IPMB
•
Controls hard drive power-on and power-down, facilitating hot-swapping