Command Switches
Description
SYS
HEALTH
QUERY
Causes the BMC to return a high level version of the system health
status in terse format. The BMC returns a string with the following
format if the command is accepted.
PWR:zzz H:xx T:xx V:xx PS:xx C:xx D:xx S:xx O:xx
Where:
•
PWR is system POWER state
•
H
is overall Health
•
T
is Temperature
•
V
is Voltage
•
PS is Power Supply subsystem
•
F
is cooling subsystem (Fans)
•
D
is hard drive / RAID Subsystem
•
S
is physical Security
•
O
is Other (OEM)
zzz is: ON, OFF (soft-off or mechanical off), SLP (sleep - used
when it cannot distinguish sleep level), S4, S3, S2, S1, ??
(unknown)
xx is: ok, nc, cr, nr, uf, or ?? where:
•
ok = OK (monitored parameters within normal operating ranges)
•
nc = non-critical
(warning: hardware outside normal
operating range)
•
cr = critical (fatal: hardware exceeding specified ratings)
•
nr = non-recoverable (potential damage: system hardware in
jeopardy or damaged)
•
uf = unspecified fault (fault detected, but severity unspecified)
•
?? = status not available/unknown (typically because system
power is OFF)