Connecting DS60 shelves
The cabling diagrams in this section show maximum configurations. Not all systems
will have all the disk shelves shown in the diagrams.
Add shelf-to-shelf cables between shelves in a loop and to the controller as shown in
the diagrams.
DS60 cable information
When connecting DS60 shelves, the same cable type connects a controller to a DS60
shelf, or a DS60 shelf to a DS60 shelf.
Table 4 DS60 cables
HD-mini-SAS connector on controller and enclosure
Cable model code
Part number
Cable length
XC-DS60-SAS-3M
038-004-380-01
3 m (118 in)
XC-DS60-SAS-4M
038-000-212-00
4 m (158 in)
XC-DS60-SAS-5M
038-000-214-00
5 m (196 in)
DD6300 with DS60 cabling
Table 5 DD6300 with DS60 cabling instructions
String
(Loop)
I/O - Port
Shelf Port
Length
a
1
I/O 7 - Port 0
A controller port 0 of the DS60.
2M
1
I/O 7 - Port 1
B controller port 0 of the DS60.
2M
a. Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be
used.
Connect Cables and Power On
Connecting DS60 shelves
27
Содержание Data Domain DD6300
Страница 1: ...Dell EMC Data Domain DD6300 System Installation Guide 302 005 015 REV 01 ...
Страница 4: ...CONTENTS 4 Data Domain DD6300 System Installation Guide ...
Страница 6: ...FIGURES 6 Data Domain DD6300 System Installation Guide ...
Страница 8: ...TABLES 8 Data Domain DD6300 System Installation Guide ...
Страница 22: ...Install the System in the Rack 22 Data Domain DD6300 System Installation Guide ...
Страница 26: ...Figure 8 DD6300 with ES30 shelves Connect Cables and Power On 26 Data Domain DD6300 System Installation Guide ...
Страница 30: ...Connect Cables and Power On 30 Data Domain DD6300 System Installation Guide ...
Страница 36: ...Configure System for Use 36 Data Domain DD6300 System Installation Guide ...