Install the system into a rack
CAUTION
Data Domain systems are heavy. Always use two people or a mechanical lift to
move a system.
Figure 4 Warning about lifting the system
CAUTION
l
The system controller should be installed in the pre-defined location for the
system controller in the rack to comply with Data Domain rack mounting
guidelines.
l
Do not apply AC power to the system controller until all expansion shelves
and cables are installed.
l
Ensure the PSNT label, which is in a slot just beneath the power supply on the
rear of the chassis is not damaged or snagged during the installation of the
system into the rack.
Procedure
1. From the front of the rack, lift the chassis to install the system in the rack in the
correct location.
2. Slide the unit onto the rails and push it fully into the cabinet until the mounting
holes on the unit are flush with the NEMA channel.
Install the System in the Rack
Install the system into a rack
17
Содержание Data Domain DD6300
Страница 1: ...Dell EMC Data Domain DD6300 System Installation Guide 302 005 015 REV 01 ...
Страница 4: ...CONTENTS 4 Data Domain DD6300 System Installation Guide ...
Страница 6: ...FIGURES 6 Data Domain DD6300 System Installation Guide ...
Страница 8: ...TABLES 8 Data Domain DD6300 System Installation Guide ...
Страница 22: ...Install the System in the Rack 22 Data Domain DD6300 System Installation Guide ...
Страница 26: ...Figure 8 DD6300 with ES30 shelves Connect Cables and Power On 26 Data Domain DD6300 System Installation Guide ...
Страница 30: ...Connect Cables and Power On 30 Data Domain DD6300 System Installation Guide ...
Страница 36: ...Configure System for Use 36 Data Domain DD6300 System Installation Guide ...