3. Open the velcro straps to route cables through the CMA. Secure the cables in
place using the velcro straps.
4. To adjust the CMA position depth (in or out), pull inward on the orange latches
(1) and pull out or push in on the arm simultaneously as needed (2).
Note
The I/O modules, the NVRAM module, the power supply units and the 2.5"
disks can be accessed for removal and replacement with the CMA in place.
Adjust the depth of the CMA arms to access these modules.
Figure 7 Adjusting the CMA depth
Installing the expansion shelves into the racks
CAUTION
l
Data Domain systems are heavy. Always use two people or a mechanical lift to
move and install a Data Domain system. Use caution to install the expansion
shelves.
l
Ensure that each rack is securely anchored to prevent tipping.
1. From the front of a rack, lift the shelf to the designated rack location.
Install the System in the Rack
20
Data Domain DD6300 System
Installation Guide
Содержание Data Domain DD6300
Страница 1: ...Dell EMC Data Domain DD6300 System Installation Guide 302 005 015 REV 01 ...
Страница 4: ...CONTENTS 4 Data Domain DD6300 System Installation Guide ...
Страница 6: ...FIGURES 6 Data Domain DD6300 System Installation Guide ...
Страница 8: ...TABLES 8 Data Domain DD6300 System Installation Guide ...
Страница 22: ...Install the System in the Rack 22 Data Domain DD6300 System Installation Guide ...
Страница 26: ...Figure 8 DD6300 with ES30 shelves Connect Cables and Power On 26 Data Domain DD6300 System Installation Guide ...
Страница 30: ...Connect Cables and Power On 30 Data Domain DD6300 System Installation Guide ...
Страница 36: ...Configure System for Use 36 Data Domain DD6300 System Installation Guide ...