*SAVE n
Saves the current configuration to non-volatile memory. The value of n must
be between 1 and 4. Example:
*SAVE 3
Saved Memory Location 3
STATUS:KEYSWITCH?
Returns whether the keyswitch is enabled or disabled. Example:
STATUS:KEYSWITCH?
Disabled
STATUS:REAR:ENABLE?
Returns whether the rear enable is enabled or disabled. Example:
STATUS:REAR:ENABLE?
Disabled
TEMP:IN?
Returns the temperature of the intake air in degrees Celsius. Example:
TEMP:IN?
27
TEMP:EXHAUST?
Returns the temperature of the exhaust air in degrees Celsius. Example:
TEMP:EXHAUST?
38 C
TRIG?
Returns the whether the trigger is internal or external. Example:
TRIG?
Internal
TRIG:EXTERNAL
Sets the trigger to External. Example:
TRIG:EXTERNAL
External