24
Dehaco B.V. • Kruisbaak 25 • 2165 AJ Lisserbroek (NL) •
✆
+31 (0)252 - 41 79 50 •
[email protected] • www.dehaco.nl
6. Maintenance
6.8 Wear limits for parts
6.8.1
Wear limit for tool and tool bushing
1) The normal clearance between the tool and its
bushing varies per model. Using the table below
the exact figures can be seen for every model.
2) Regular inspections are advised of both tool and
tool bushes. If the tool or either of these bushes
have reached the wear limit they should be
immediately replaced to prevent unnecessary
damage occurring to other parts of the breaker.
Max. wear
Check wear at surface
Wear limit
Upper bushing
(1)
Tool
(2)
Tool bushing
(3)
New
Reject
New
Reject
New
Reject
IBEX 130GS
4 mm
-
-
44,5 mm
42,5 mm
44,5 mm
46,5 mm
IBEX 135GS
4 mm
-
-
40 mm
38 mm
40 mm
42 mm
IBEX 170GS
4 mm
-
-
53 mm
51 mm
53 mm
55 mm
IBEX 200GS
4 mm
-
-
59,5 mm
57,5 mm
59,5 mm
61,5 mm
IBEX 320GS
4 mm
68 mm
70 mm
68 mm
66 mm
70 mm
68 mm
IBEX 400GS
4 mm
75 mm
77 mm
74,5 mm
72,5 mm
74,5 mm
76,5 mm
IBEX 600GS
4 mm
85 mm
88 mm
85 mm
82 mm
85 mm
88 mm
IBEX 900GS
5 mm
100 mm
102,5 mm
100 mm
96,5 mm
100 mm
102,5 mm
IBEX 1200GS
6 mm
120 mm
123 mm
120 mm
117 mm
120 mm
123 mm
IBEX 1800GS
6 mm
135 mm
140 mm
135 mm
133 mm
135 mm
140 mm
IBEX 2200GS
6 mm
150 mm
153 mm
150 mm
147 mm
150 mm
156 mm
IBEX 2800GS
6 mm
153 mm
156 mm
153 mm
150 mm
153 mm
156 mm
IBEX 3200GS
6 mm
160 mm
166 mm
160 mm
157 mm
160 mm
166 mm
IBEX 4000GS
6 mm
180 mm
183 mm
180 mm
177 mm
180 mm
183 mm