10
Picture 10
.
Dimensions of DEFRO HOME VITAL 51 S BL and DEFRO
HOME VITAL 51 BP (mirror reflection).
Picture 11
.
Dimensions of DEFRO HOME VITAL 51 S C.
4.3.
EQUIPMENT
The gas-fired heater is delivered on a pallet, foil-wrapped and are
fully assembled. Scope of delivery can include additional components
and subassemblies, according to the order of the user. Standard
components of the equipment are specified in the table 2.
Table 3. Equipment of DEFRO HOME VITAL room heater.
Standard equipment of gas fireplace
Unit
Quan
tity
Equipment operating manual
pcs.
1
Operating manual and warranty card for electronic
controller
pcs.
1
Controller with a valve
set
1
4.4.
FUEL PARAMETERS
Gaseous fuel of second or third family acc. to the EN 437 standard
is used as a primary fuel for the DEFRO HOME VITAL heater.
The heater is factory adapted to one type of fuel acc. to the
customer’s order and can be operated only with this fuel.
Conversion of the equipment to the other type of fuel and
change of gas on your own and without conversion is
forbidden!
Contact the manufacturer if it is required to change a fuel
type.
4.5.
SPARE PARTS
To obtain information on availability of spare parts for gas-fired
fireplace or inquiries about equipment servicing please contact with
DEFRO Service Center or Authorized DEFRO Service.
DEFRO Sp. z o.o. Sp. k
Centrum Serwisowe
Ruda Strawczyńska 103a
26-067 Strawczyn
@
5.
TRANSPORT
Room heater in the packing material should be transported in the
horizontal position using a special trolley. In special cases and on short
distances, it is allowed to transport it in vertical position.
6.
SYSTEM
Check the local conditions for distribution before
installation (identify type of gas and its pressure) and
whether the current settings of a heater are correct.
VITAL heater should be supplied with the same type of gas
as the other gas-fired equipment (if any) in the home of their
installation.
Installation of the gas-fired heater should be performed by qualified
personnel. All assembly operations should be performed in accordance
with the applicable national and local regulations within the scope of
fire protection, requirements of gas distributor and local authorities.
Gas system and flue gas handling system should be in compliance
with the Regulation of the Minister of Infrastructure of 12.04.2002
(Journal of Laws of 2002, no. 75, item 690) with all subsequent acts
amending this regulation.
Obtain all necessary consents from the appropriate authorities
before the installation: Regional gas company, chimney sweeping
company and building administration.
6.1.
INSTALLATION LOCATION
Selection of installation location of the gas-fired heater should be
based on meeting of the following conditions:
access to gas piping system should ensure ease of
connection; flexible hoses should not be excessively twisted;
access to chimney system should ensure as low number of
bends as possible;
Distance of the heater from non-flammable components of
the housing should not be smaller than 80 mm and
temperature of walls exposed to direct heating by the heater
should not exceed 80
⁰
C.
The room heater is intended for installation only in vertical position
and should be placed on hard and non-flammable substrate with
suitable load-carrying capacity. It is forbidden to install the heater as a
unit hanging on the wall!
6.2.
CONNECTION TO THE GAS PIPING SYSTEM
The device is intended only for one type of fuel acc. to the
customer’s orders indicated on the first page of the manual
and declaration on the rating plate.
848
94
9
8
3
5
5
1
0
850
2
9
7
49
Ø
150
329
741
247
4
9
0
989
50
>9
63
330
29
7
Ø
150
889
5
1
0
1
1
5
9
8
783
189
5
0
0
Содержание VITAL 37S
Страница 28: ...28 gas holes left corner of the burner...
Страница 31: ...31 right corner of the burner...
Страница 40: ...40...
Страница 42: ......
Страница 44: ......
Страница 46: ......
Страница 50: ......
Страница 51: ...51...