message string. If '
$
' is used, a 50ms minimum delay is inserted before a reply is
sent. If '
*
' is used, a 2ms minimum delay is inserted before a reply is sent.
Custom ASCII Read/Write Examples
Example
Description
SR$
Read display value from all controllers, 50ms delay.
S15R$
Read display value from controller address 15, 50ms delay.
S3U40*
Read unformatted data in channel 4 from controller address 3, 2ms delay.
S2W2 –10000$
Write
–
10000 to the display register of controller address 2, 50ms delay.
SWT CHAN_1$
Write ASCII text string Chan_1 to channel 1 text register, 50ms delay.
Controller Response -
After the controller has completed a read or write instruction,
it responds by sending a carriage return/line feed (CR/LF) back to the host. If
the instruction was a read command, the CR/LF follows the last character in the
ASCII string. If it was a write command, CR/LF is the only response sent back.
The host must wait for this before sending further commands to the controller.
If the controller encounters an error, it will respond with a null (0x00) CR/LF.
16 Bit Unsigned
Address
Function
1
Alarm status (SP1=Bit 0, SP2=Bit
1, SP3=Bit 2, SP4=Bit 3)
65–68
Hysteresis (SP1=65, SP2=66, SP3
=67, SP4=68)
71–74
Make delay (SP1=71, SP2=72, SP
3=73, SP4=74)
32 Bit Signed
Address
Function
3
Tared/Batch weight (net)
4
mV
39
Live weight (gross)
16
Tare value
12
Peak
13
Valley
6–9
Setpoint 1
–
4 (SP1=6, SP2=7, SP3
=8, SP4=9)
34
D/A scale low value
36
D/A scale high value