Rounding is quoted in display counts and is not influenced by decimal point position. For exam-
ple, if your input signal is 5.3, the display will show: 5.3 (for rounding=NONE), 5.4 (for round-
ing=2), 5.5 (for rounding=5), 5.0 (for rounding=10), etc.
F
_ _ _ MODE
scrolls across the display and toggles with the current weighing
mode. Use the
and
buttons to select
NORMAL
(default) or
BATCH
, and
then press
.
¨
If you selected
NORMAL
, skip to 6.2H now.
¨
If you selected
BATCH
, continue to 6.2G now.
In
NORMAL
(default) mode the controller displays the gross or net weight on the display, and
does not perform any batch calculations. In
BATCH
mode the controller displays batch or gross
weight, and SP 1 and SP 2 function as dedicated batch control setpoints (see 2.1).
G _ _ _ BATCHING DIRECTION
scrolls across the display and toggles with current
selection. Use the
and
buttons to select either:
LIW
(loss in weight, for
emptying operations) or
GIW
(gain in weight, for filling operations). Press
.
See Section 2.1 for additional information.
For 6.2H–K, please refer to the list of input functions in Appendix A.
H _ _ _ PROG BUTTON
scrolls across the display and toggles with the current
selection. Referring to the table in Appendix A, use the
and
buttons
to select a function to be performed when the
button is pressed:
HOLD
,
TARE
1
,
BATCH
2
,
ZERO
,
PEAK
,
PK RST
or
. Then press
.
I
_ _ _ USER INPUT1
scrolls across the display and toggles with the current selec-
tion. This controls the function that will be performed when the User 1 input pin
at the rear of the meter (see 4.6) is activated. Referring to the table in Appendix
A, use the
and
buttons to select:
LOCK
,
TARE
1
,
BATCH
2
,
ZERO
,
PEAK
,
PK RST
,
,
GROSS
,
START
2
or
STOP
2
. Then press
.
J
_ _ _ USER INPUT2
scrolls across the display and toggles with the current selec-
tion. This controls the function that will be performed when the User 2 input pin
at the rear of the meter (see 4.6) is activated. Referring to the table in Appendix
A, use the
and
buttons to select:
HOLD
,
TARE
1
,
BATCH
2
,
ZERO
,
PEAK
,
PK RST
,
,
GROSS
,
START
2
or
STOP
2
. Then press
.