4.8
Room temperature for a zone
4.8.1
Selecting the operating mode
To set the room temperature for the different living zones, you can choose
between five operating modes. We recommend the Scheduling operating
mode which enables the room temperature to be modulated according to
your needs and to optimise your energy consumption.
1. Select the icon for the affected zone,
, for example.
2. Select the desired operating mode:
Tab.18
Mode
Description
Scheduling
The room temperature is modulated according to the timer programme chosen.
Recommended mode.
Manual
The room temperature is constant.
Short temperature change
The room temperature is forced for a defined period.
Holiday
The room temperature is reduced during an absence period to save energy.
Antifrost
The installation and equipment are protected against frost during the winter peri
od.
4.8.2
Activating and configuring a timer programme for heating
A timer programme can be used to vary the room temperature in a living
zone depending on activities during the day. This can be programmed for
each day of the week.
1. Select the icon for the zone to be programmed,
, for example.
Information on the current operating mode is given in the upper part
of the screen.
2. To activate the timer programming or to change the timer programme,
select Scheduling.
3. Select the timer programme to be activated.
Information on the active timer programme is given in the upper part
of the screen.
4. To modify the timer programme, select Zone configuration > Heating
Schedule.
5. Select the programme to be modified.
The programmed activities for Monday are displayed.
The last activity of the day remains active until the first activity of the
following day.
6. Select the day to be modified.
7. Carry out the following actions according to your needs:
Modify the timings for programmed activities.
Add a new time range.
Delete a programmed activity (choose the activity "Delete").
Copy programmed daily activities to other days.
Modify temperatures linked to an activity.
4.8.3
Activating and configuring a timer programme for cooling
You can modify the timer programme linked to the Cooling mode. In the
Scheduling operating mode, the Cooling timer programme is activated
automatically when the average outdoor temperature over a 24-hour
period has been greater than 22 °C. If you would prefer that this mode is
triggered at a different temperature, ask your installer to modify this
parameter in your installation.
Off
Off
Fig.6
MW-5000770-04
Heating Schedule
Zone setup: ...
Zo..
14 : 23
Monday
6:00
Comfort
20.0°C
Edit schedule entry
6:00
Comfort
20.0°C
22.00
Reduce
16.00°C
Add time and Activity
Copy to other day
Set activity temperatures
4 Operation
22
MIT-S
7684505 - v03 - 14052020
Содержание HPI S
Страница 41: ...10 Appendix 7684505 v03 14052020 MIT S 41...