1. Select the icon for the zone to be modified,
, for example.
2. Select Zone configuration > Zone friendly Name.
3. Modify the name of the zone (20 characters max.).
4. Select Icon display zone
5. Select the symbol to be associated with the zone.
6. Enter the chosen name and symbol in the table provided at the back
of the manual.
4.7
Personalising the activities
4.7.1
Activity
This term is used when programming time ranges. It refers to the client's
desired comfort level for different activities during the course of the day.
One set point temperature is associated to each activity. The last activity
of the day remains valid until the first activity of the following day.
Tab.17 Example:
Start
of the activity
Activity
Set point temperature
6:30
Morning
1
20 °C
9:00
Away
2
19 °C
17:00
Home
3
20 °C
20:00
Evening
4
22 °C
23:00
Sleep
5
16 °C
4.7.2
Changing the name of an activity
The name of the different activities is factory-set: Sleep, Home, Away,
Morning, Evening and Custom. If you desire, you can personalise the
name of the activities for all of the zones in your installation.
1. Press the key.
2. Select System Settings.
3. Select Set Heating Activity Names or Set Cooling Activity Names.
4. Select the activity you want to change.
5. Change the name of the activity (10 characters max.).
4.7.3
Changing the temperature of an activity
The temperatures for the different activities are factory-set as shown in the
appendix. If you desire, you can personalise the temperatures for these
activities for all of the zones in your installation. These activities are used
in the timer programmes.
1. Select the icon for the zone to be programmed,
, for example.
2. Select Set Heating Activity Temperatures, either for heating or for
cooling.
Information on the selected menu is given in the lower part of the
screen.
3. Select the activity you want to change.
4. Modify the temperature for the activity.
5. Enter the chosen temperature in the table provided at the back of the
manual.
Fig.5
MW-1001144-2
°C
16
06:30
09:00
17:00
20:00
23:00
19
20
22
5
1
2
3
4
5
4 Operation
7684505 - v03 - 14052020
MIT-S