13 Appendix
13.1 Product fiche - Heat pump space heaters
Tab.23 Product fiche for heat pump space heaters
GSHP 5
MR-E
GSHP 5 TR-
E
GSHP 9
MR-E –
GSHP 9 TR-
E
GSHP 12
MR-E –
GSHP 12
TR-E
GSHP 15
TR-E
Space heating energy efficiency class under average cli
mate conditions
A
++
A
++
A
++
A
++
Rated heat output under average climate conditions
(Prated or Psup)
kW
7
12
15
21
Seasonal space heating energy efficiency under aver
age climate conditions
%
177
181
173
177
Annual energy consumption
kWh
2951
5291
6968
9224
Sound power level L
WA
indoors
(1)
dB (A)
49
53
52
51
Rated heat output, under colder - warmer climate condi
tions
kW
7 - 7
12 - 12
15 - 15
21 - 21
Seasonal space heating energy efficiency, under colder
- warmer climate conditions
%
185 - 176
187 - 181
180 - 174
183 - 177
Annual energy consumption colder - warmer
kWh
3372 - 1921 6094 - 3420 8027 - 4494 10629 -
5939
Sound power level L
WA
outdoors
dB (A)
0
0
0
0
(1) If applicable
Tab.24 Product fiche for heat pump space heaters
GSHP 19 TR
GSHP 27 TR
Space heating energy efficiency class under average climate conditions
A
++
A
++
Rated heat output under average climate conditions
(Prated or Psup)
kW
26
34
Seasonal space heating energy efficiency under average climate condi
tions
%
170
159
Annual energy consumption
kWh
11987
16627
Sound power level L
WA
indoors
(1)
dB (A)
53
50
Rated heat output, under colder - warmer climate conditions
kW
26 - 26
34 - 34
Seasonal space heating energy efficiency, under colder - warmer climate
conditions
%
176 - 171
163 - 160
Annual energy consumption colder - warmer
kWh
13834 - 7709
19291 - 10690
Sound power level L
WA
outdoors
dB (A)
0
0
(1) If applicable.
See
For specific precautions about assembling, installing and main
taining: See Safety Instructions
13 Appendix
7636860 - v04 - 18012017
GSHP
47