3 Technical specifications
3.1
Homologations
3.1.1
Directives
This product complies with the requirements of the following European Di
rectives and Standards:
Pressure Equipment Directive 97/23/EC, Article 3, paragraph 3
Low Voltage Directive 2014/35/EU
Generic standard: EN 60335-1
Relevant standard: EN 60335-2-40
Electromagnetic Compatibility Directive 2014/30/EU
Generic standards: EN 61000-6-3, EN 61000-6-1
Relevant Standard: EN 55014
This product conforms to the requirements of European Directive
2009/125/EC on the ecodesign of energy-related products.
In addition to the legal requirements and guidelines, the supplementary
guidelines in this manual must also be followed.
Supplements or subsequent regulations and guidelines that are valid at
the time of installation shall apply to all regulations and guidelines speci
fied in this manual.
3.2
Technical data
3.2.1
Conditions of use
Tab.3
Pressure limitations
Maximum operating pressure of the heating circuit
0.3 MPa (3 bar)
Maximum operating pressure of the collector circuit
0.3 MPa (3 bar)
Tab.4
Temperature limitations
Limit operating temperatures on the heating circuit in Heating mode
+7°C / +80°C
Limit operating temperatures on the heating circuit in Cooling mode
+7°C / +25°C
Limit operating temperatures on the collection circuit (source)
-15 °C / +35 °C
3.2.2
Heat pump
Tab.5
Performances for a glycol water/water system (0°C/-3°C and 30°C/35°C), in accordance with NF EN 14511–1
Measurement
type
Unit
GSHP 5
MR-E
GSHP 5
TR-E
GSHP 9
MR-E
GSHP 9
TR-E
GSHP
12 MR-E
GSHP
12 TR-E
GSHP
15 TR-E
GSHP
19 TR
GSHP
27 TR
Power supply
V
(~50 Hz)
230
single
phase
400
three-
phase
230
single
phase
400
three-
phase
230
single
phase
400
three-
phase
400
three-
phase
400
three-
phase
400
three-
phase
Coefficient of
performance
(COP)
4.38
4.38
4.39
4.39
4.35
4.35
4.50
4.28
4.10
Absorbed electri
cal power
kW
1.30
1.30
2.25
2.25
2.91
2.91
3.80
4.76
6.83
Application flow
rate
m
3
/h
0.98
0.98
1.70
1.70
2.18
2.18
2.95
3.52
4.83
3 Technical specifications
14
GSHP
7636860 - v04 - 18012017