8.2
Troubleshooting
8.2.1
Anti-hunting
When the appliance is in Anti-hunting operating mode, the
symbol
flashes.
1. Go to the message by pressing the
key.
The message ¤Operation assured when the restart temperature
will be reached is displayed. This message is not an error code. It
is intended for information purposes only.
8.2.2
Deleting sensors from the PCB memory
The sensor configuration is memorised by the SCU PCB. If an error occurs
when the corresponding sensor has not yet been connected or has been
removed on purpose, delete the sensors from the PCB memory.
1. Go to the message: REMOVE? by pressing the
key several
times.
2. Select the answer ON by turning the settings button.
3. Confirm the selection by pressing the settings button.
Important
The outside temperature sensor cannot be deleted.