16
3.6 Checking micro-switches and sensors
N°
Description
Activated
Deactivated
Notes
1
Geared motor micro-
switch WORK
Distributor in WORK
position
Distributor not in
WORK position
2
Geared motor micro-
switch HOME
Distributor in HOME
position
Distributor not in
HOME position
3
Front command strip
micro-switch
Command strip closed
Command strip
open
5
COFFEE GROUNDS TRAY
micro-switch
Tray present
Tray absent
6
DISTRIBUTION GROUP
micro-switch
Present
Absent
7
DOOR Micro-switch
Door closed
Door open
8
FLOW METER
The technician
can check the
impulses
9
COFFEE GRINDER
IMPULSES
The technician
can check the
impulses
0
WATER LEVEL in the
tank
Level is OK
Level is LOW
A
WATER ALARM micro-
switch
Water detected in the
bottom of the machine
No water detected
in the bottom of the
machine.
M Coffee holder empty
There is no coffee
There should be
coffee.
This is derived
and not
hardware data.
R
CLOCK (shows seconds) Even seconds
Odd seconds
It should flash at
1 HZ
K
FRONT FACE PRESENT
Present
Absent
0-8 COFFEE GRINDER
SETTINGS
Factory settings
*
COFFEE GRINDER
SETTINGS SAVED
Not saved
Saved
Содержание DED700X
Страница 3: ...3 REV 00 CHAPTER 1 INTRODUCTION ...
Страница 5: ...5 REV 00 CHAPTER 2 TECHNICAL INFORMATION ...
Страница 6: ...6 2 1 Internal components ...
Страница 8: ...8 REV 00 CHAPTER 3 PROGRAMMING DIAGNOSTICS AND TESTS ...
Страница 17: ...17 REV 00 CHAPTER 4 DIAGRAMS ...
Страница 18: ...18 4 1 Cabling diagram ...
Страница 20: ...20 4 2 Hydraulics diagram ...
Страница 21: ...21 REV 00 CHAPTER 5 OPERATING LOGIC ...
Страница 24: ......
Страница 27: ......
Страница 29: ...29 REV 00 CHAPTER 6 FITTING AND REMOVING COMPONENTS ...
Страница 32: ...32 Remove the indicated screws Cut the clamp Remove the cabling and then the upper board by lifting it ...
Страница 44: ...44 REV 00 CHAPTER 7 EXPLODED VIEWS ...
Страница 45: ...45 7 1 Exploded view ...
Страница 46: ...46 ...
Страница 47: ...47 Esp E90046 ...
Страница 50: ...50 REV 00 CHAPTER 8 PROBLEMS CAUSES SOLUTIONS ...