11
3.2 Diagnostics Mode
To go to “diagnostics mode” turn on the machine is displayed.
Within the first 5 seconds, press the
8-9-8-2
keys in order to display
and then press
OK
to display
The programming menu is displayed.
Keys “
2
” and “
3
” are used to scroll through the settings.
Key “
4
” is used to change the settings and confirm.
Key “
1
” is used to quit diagnostics mode.
MACHINE SETTINGS
SETTING RANGE
FUNCTION
1
1 Large coffee – 520 impulses
50 – 800
Number of pump impulses to make a large coffee
2
1 Expresso – 170 impulses
50 – 800
Number of pump impulses to make an expresso coffee
3
1 Coffee – 290 impulses
50 – 800
Number of pump impulses to make a coffee
4
Hot Water – 260 impulses
50 - 800
Number of pump impulses to distribute hot water
5
Steam timer 20 seconds
5 - 120
6
K1 Setting K1 Value 8
1 – 50
K1 is the temperature rise factor. High value = high factor
(do
not modify the selected value)
7
K2 Setting K2 Value 30
1 – 50
K2 is the influence of frequency of use on the temperature
setting. High value = low influence
(do not modify the selected
value)
8
Normal temperature 90 °C
70 – 130 °C
Normal temperature
9
High temperature 110 °C
70 – 130 °C
High temperature
10
Temperature of the 1st coffee
117 °C
70 – 130 °C
Temperature of the first coffee
11
Total grounds 0
0 – 50
Coffee grounds counter
12
Stop grounds 12
0 - 50
Limit beyond which the coffee grounds tray should be emptied
13
Total water
0
Boiler 1 total distributed water
(not modifiable)
14
De-scaling water ml --
0
When the set value is reached the “de-scale” message is
displayed
(not modifiable)
15
Water filter ml --
Quantity of water filtered since the Aqua Prima filter was
activated
16
H2O after de-scaling message
ml --
0
Quantity of water used since the “de-scale” message was
displayed
17
Hot water flow l/h 20
06 - 26
Flow in l/h during hot water distribution
18
Hot water pump settings
62430
Pump settings for water distribution
(do not modify the selected
value)
19
Water tank – number of
impulses 0
0
Water tank counter
20
Water tank stop – n° of impulses
750
Water tank stop
SELECT FUNCTION
MACHINE READY
Software
Programming
energy saving
Auto-diagnostic
Содержание DED700X
Страница 3: ...3 REV 00 CHAPTER 1 INTRODUCTION ...
Страница 5: ...5 REV 00 CHAPTER 2 TECHNICAL INFORMATION ...
Страница 6: ...6 2 1 Internal components ...
Страница 8: ...8 REV 00 CHAPTER 3 PROGRAMMING DIAGNOSTICS AND TESTS ...
Страница 17: ...17 REV 00 CHAPTER 4 DIAGRAMS ...
Страница 18: ...18 4 1 Cabling diagram ...
Страница 20: ...20 4 2 Hydraulics diagram ...
Страница 21: ...21 REV 00 CHAPTER 5 OPERATING LOGIC ...
Страница 24: ......
Страница 27: ......
Страница 29: ...29 REV 00 CHAPTER 6 FITTING AND REMOVING COMPONENTS ...
Страница 32: ...32 Remove the indicated screws Cut the clamp Remove the cabling and then the upper board by lifting it ...
Страница 44: ...44 REV 00 CHAPTER 7 EXPLODED VIEWS ...
Страница 45: ...45 7 1 Exploded view ...
Страница 46: ...46 ...
Страница 47: ...47 Esp E90046 ...
Страница 50: ...50 REV 00 CHAPTER 8 PROBLEMS CAUSES SOLUTIONS ...