14
Pressured up pump operation
Key 1 + 7
To check that the pump is pressured up. (this is done to check for eventual leaks inside the machine)
Steam boiler electric current
Key 4 + 6
Check the electric current using an ammeter.
During the temperature rise approx. :
4.8 A (230 V);
9 A (120V);
11 A (100V)
Coffee boiler electric current
Key 2 + 6
Check the electric current using an ammeter.
Boiler temperature
Key 4 + 6 + 7
This function is used to check the current temperature of the coffee boiler
Contrast LCD Key 1 + 6 + 7
Back-light LCD Key 2 + 6 + 7
3.4 Checking micro-switches in Test Mode
Display
N°
Micro-switch
Function
1
Geared motor in distribution
phase switch
It sets the stopping point of the group’s rise
2
Geared motor on standby
switch
It sets the stopping point of the group’s descent
3
Panel switch
5
Coffee ground tray and drip
tray switch
Detects the presence of the coffee grounds tray and the drip tray
6
Coffee group switch
Detects the presence of the coffee group
7
Door switch
Detects the correct shutting of the door
8
Turbine sensor
Counts the turbine impulsions in order to define the quantity of water to
be used when making the coffee
9
Coffee grinder sensor
Defines the number of revolutions depending on the dose of coffee
0
Water sensor
Detects when there is insufficient water in the tank
A
Water tank safety sensor
Detects when the water tank is full
M
No Coffee
Detects when there is no more coffee in the coffee holder
R
RTC control
Detects correct function of the clock (it should blink)
K
Facade detector
Detects the presence of the facade
0-8
Coffe grinder setting
Detects the coffee grinder settings in factory control phase
*
Coffee grinder impulses
Indicates whether the value on the previous line (0-8) was saved
Содержание DED700X
Страница 3: ...3 REV 00 CHAPTER 1 INTRODUCTION ...
Страница 5: ...5 REV 00 CHAPTER 2 TECHNICAL INFORMATION ...
Страница 6: ...6 2 1 Internal components ...
Страница 8: ...8 REV 00 CHAPTER 3 PROGRAMMING DIAGNOSTICS AND TESTS ...
Страница 17: ...17 REV 00 CHAPTER 4 DIAGRAMS ...
Страница 18: ...18 4 1 Cabling diagram ...
Страница 20: ...20 4 2 Hydraulics diagram ...
Страница 21: ...21 REV 00 CHAPTER 5 OPERATING LOGIC ...
Страница 24: ......
Страница 27: ......
Страница 29: ...29 REV 00 CHAPTER 6 FITTING AND REMOVING COMPONENTS ...
Страница 32: ...32 Remove the indicated screws Cut the clamp Remove the cabling and then the upper board by lifting it ...
Страница 44: ...44 REV 00 CHAPTER 7 EXPLODED VIEWS ...
Страница 45: ...45 7 1 Exploded view ...
Страница 46: ...46 ...
Страница 47: ...47 Esp E90046 ...
Страница 50: ...50 REV 00 CHAPTER 8 PROBLEMS CAUSES SOLUTIONS ...