6 Settings
6.1
Modifying the User parameters
Caution
Altering the factory settings may impair operation of the appliance.
1. Go to the User menu.
2. Select the desired sub-menu by pressing the or key.
3. Confirm the selection by pressing the
key.
4. Select the required parameter by pressing the or keys to scroll
through the list of adjustable parameters.
5. Confirm the selection by pressing the
key.
6. Modify the value of the parameter using the or keys.
7. Confirm the new value of the parameter by pressing the
key.
8. Go back to the main display by pressing the
h
key.
6.2
User menu
Fig.32
1
2
MW-2000435-1
3
2
1 Sub-menu available
2 Name of the PCB or circuit
3 Setting parameters
Tab.20 List of User sub-menus
Sub-menu
Description
Name of the PCB or circuit
CIRCA
Main heating circuit
EHC–04
CIRCB
Additional heating circuit B
SCB-04
ECS
Domestic hot water circuit
EHC–04
EHC–04
EHC–04 central unit PCB
EHC–04
SCB-04
Additional PCB for circuit B
SCB-04
HMI
HMI control panel
HMI
6.2.1
User \CIRCA and CIRCB menu
CP : Circuits Parameters = Heating circuit parameters
Tab.21
Parameter
Description
Factory setting
CIRCA
Factory setting
CIRCB
CP010
Zone flow temperature setpoint, used when the zone is set to a fixed
flow setpoint.
not available
50
CP080
Room setpoint temperature of the user zone activity
Can be set from 5 °C to 30 °C
16
16
CP081
Room setpoint temperature of the user zone activity in activity zone
2
Can be set from 5 °C to 30 °C
20
20
Fig.30
MW
-5
0
0
0
0
0
8
-2
Fig.31
MW
-5
0
0
0
0
4
0
-6
6 Settings
32
7611444 - v06 - 04032019
Содержание AWHP 6MR-EMC 24/28 MI HYBRIDE