Parameter
Description
Factory setting
CIRCA
Factory setting
CIRCB
CP082
Room setpoint temperature of the user zone activity in activity zone
3
Can be set from 5 °C to 30 °C
6
6
CP083
Room setpoint temperature of the user zone activity in activity zone
4
Can be set from 5 °C to 30 °C
21
21
CP084
Room setpoint temperature of the user zone activity in activity zone
5
Can be set from 5 °C to 30 °C
22
22
CP085
Room setpoint temperature of the user zone activity in activity zone
6
Can be set from 5 °C to 30 °C
23
20
CP140
Setpoint of the room cooling temperature of the zone: cooling activity
zone 1
Can be set from 20 °C to 30 °C
30
30
CP141
Setpoint of the room cooling temperature of the zone: cooling activity
zone 2
Can be set from 20 °C to 30 °C
25
25
CP142
Setpoint of the room cooling temperature of the zone: cooling activity
zone 3
Can be set from 20 °C to 30 °C
25
25
CP143
Setpoint of the room cooling temperature of the zone: cooling activity
zone 4
Can be set from 20 °C to 30 °C
25
25
CP144
Setpoint of the room cooling temperature of the zone: cooling activity
zone 5
Can be set from 20 °C to 30 °C
25
25
CP145
Setpoint of the room cooling temperature of the zone: cooling activity
zone 6
Can be set from 20 °C to 30 °C
25
25
CP200
Manually setting the room temperature setpoint of the zone
Can be set from 5 °C to 30 °C
20
20
CP320
Operating mode of the zone
0 = timer programming
1 = manual mode
2 = frost protection mode
0
0
CP350
Comfort Domestic Hot Water Temperature Setpoint of zone
Can be set from 40 °C to 80 °C
not available
55
CP360
Reduced Domestic Hot Water Temperature Setpoint of zone
Can be set from 10 °C to 60 °C
not available
10
CP510
Temporary room setpoint per zone
Can be set from 5 °C to 30 °C
20
20
CP540
Setpoint of swimming pool when Zone is configured on Swimming
Pool
Can be set from 0 °C to 39 °C
not available
20
CP550
Fire Place mode is active
0 = off
1 = on
0
0
6 Settings
7611444 - v06 - 04032019
33
Содержание AWHP 6MR-EMC 24/28 MI HYBRIDE