Tab.17 Outdoor unit
Weight (empty)
Unit
AWHP 4.5 MR
AWHP 6 MR-3
AWHP 8 MR-2
Outdoor unit
kg
54
42
75
3.2.4
Technical data - Low-temperature heat pump
combination heaters
Tab.18 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
AWHP 4.5MR–
EMC 24/28 MI
HYBRIDE
AWHP 6MR3–
EMC 24/28 MI
HYBRIDE
AWHP 8MR–
EMC 24/28 MI
HYBRIDE
Air-to-water heat pump
Yes
Yes
Yes
Water-to-water heat pump
No
No
No
Brine-to-water heat pump
No
No
No
Low-temperature heat pump
No
No
No
Equipped with a supplementary heater
Yes
Yes
Yes
Heat pump combination heater
Yes
Yes
Yes
Rated heat output under average conditions
Prated
kW
8
8
11
Rated heat output under colder conditions
Prated
kW
6
6
9
Rated heat output under warmer conditions
Prated
kW
4
5
6
Declared capacity for heating for part load at an
indoor temperature of 20 °C and outdoor temper
ature
T
j
T
j
= -7°C
Pdh
kW
3.8
3.5
5.6
T
j
= +2 °C
Pdh
kW
4.3
4.5
6.1
T
j
= +7 °C
Pdh
kW
4.5
4.8
6.4
T
j
= +12 °C
Pdh
kW
5.5
5.2
6.5
T
j
= bivalent temperature
Pdh
kW
4.3
4.5
6.1
T
j
= operation limit temperature
Pdh
kW
3.9
3.6
5.6
Bivalent temperature
T
biv
°C
2
2
2
Degradation co-efficient
Cdh
—
1.0
1.0
1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
%
136
133
135
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
%
122
122
125
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
%
172
166
169
Declared coefficient of performance or primary
energy ratio for part load at an indoor tempera
ture of 20 °C and outdoor temperature
T
j
T
j
= -7°C
COPd
-
or
%
1.64
1.86
1.95
T
j
= +2 °C
COPd
-
or
%
3.46
3.40
3.49
T
j
= +7 °C
COPd
-
or
%
4.96
4.52
4.57
T
j
= +12 °C
COPd
-
or
%
7.35
6.70
6.33
3 Technical specifications
20
7611444 - v06 - 04032019
Содержание AWHP 6MR-EMC 24/28 MI HYBRIDE