7 Reading out measured values
The measured values are available in the Information menu of the
different PCBs.
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Tab.32 Choosing the menu
Counters
Selection
Measured values on circuit A
Choose the EHC–04 menu
Measured values on circuit B
Choose the SCB-04 menu
Measured values connected to the
operation of the heat pump
Choose the EHC–04 menu
Tab.33 Values available (X) in the sub-menus EHC–04, SCB-04
Parameter
Description
Unit
EHC–04
SCB-04
AM002
"Silent mode" status
X
AM010
The current pump speed
%
X
AM012
Current main status of the appliance.
See
Control system sequence chapter
X
X
AM014
Current sub status of the appliance.
See
Control system sequence chapter
X
X
AM015
Is the pump running?
X
AM016
Flow temperature of appliance.
°C
X
AM019
Water pressure of the primary circuit.
bar
X
AM027
Instantaneous outside temperature
°C
X
X
AM040
Temperature used for hot water control algorithms.
°C
X
AM056
Wate flow rate in the system
l/min
X
AM091
Seasonal mode active (summer / winter)
0: Winter
1: Frost protection
2: Summer neutral band
3: Summer
X
X
AM101
Internal system flow temperature setpoint
X
CM030
Measure of the room temperature of the zone
°C
X
X
CM040
Measure Zone Flow Temperature or DHW
temperature
°C
X
CM060
Current Pump speed of zone
%
X
CM120
Zone Current Mode:
0 = Scheduling
1 = Manual
2 =Antifrost
3 =Temporary
X
X
CM130
Current activity of the zone:
0 = Anti frost
1 =Reduced
2 =Comfort
3 =Anti legionella
X
X
CM190
Wished room temperature setpoint of the zone
°C
X
X
CM210
Current outdoor temperature of the zone
°C
X
X
7 Reading out measured values
42
7611444 - v06 - 04032019