background image

10  Environmental

10.1  Energy savings

Tips on saving energy:

Do not block ventilation outlets.

Do not cover the radiators. Do not hang curtains in front of the radiators.

Install reflective panels behind the radiators to prevent heat losses.

Insulate the pipes in rooms that are not heated (cellars and lofts).

Turn off the radiators in rooms not being used.

Do not run hot (or cold) water pointlessly.

Install a water-saving shower head to save up to 40% energy.

Take showers rather than baths. A bath consumes twice as much water 

and energy.

10.2  Room thermostat and settings

Various models of room thermostat are available. The type of thermostat 

used and the parameter selected impact total energy consumption.

A modulating regulator, which may be combined with thermostatic 

valves, is eco-friendly in terms of energy and offers an excellent level of 

comfort. This combination allows you to set the temperature separately 

for each room. However, do not install thermostatic radiator valves in the 

room in which the room thermostat is located.

Complete opening and closing of the thermostatic radiator valves cau­

ses undesirable variations in temperature. Therefore, these must be 

opened/closed progressively.

Set the room thermostat to a temperature of approximately 20°C to re­

duce heating costs and energy consumption.

Lower the thermostat setting to approximately 16°C at night or when you 

are not at home. This reduces heating costs and energy consumption.

Lower the thermostat setting well before airing the rooms.

Set the water temperature to a lower level in summer than in winter (e.g. 

60°C and 80°C respectively) when an ON/OFF thermostat

is used.

When clock thermostats and programmable thermostats are to be set, 

do not forget to take any holidays and days when no one is at home into 

account.

10 Environmental

7611973 - v04 - 07032016

AWHP-2 MIV-3

33

Содержание AWHP-2 MIV-3

Страница 1: ...en User Guide Reversible air water Split Inverter heat pump ALEZIO EVOLUTION AWHP 2 MIV 3...

Страница 2: ...ng the product and keep it in a safe place for future reference In order to ensure continued safe and efficient operation we recommend that the product is regularly maintained Our Service and After Sa...

Страница 3: ...the control panel 19 5 2 Starting the heat pump 19 5 3 Switching off the central heating 19 5 4 Frost Protection 19 6 Settings 21 6 1 List of parameters 21 6 1 1 Choosing the hybrid operating mode 21...

Страница 4: ...sposal recycling 34 11 1 Disposal and Recycling 34 12 Warranty 35 12 1 General 35 12 2 Terms of warranty 35 13 Appendix 36 13 1 Product fiche 36 13 2 Product fiche Temperature Controls 36 13 3 Package...

Страница 5: ...es 5 Evacuate the property 6 Contact a qualified professional Danger of electric shock Before any work switch off the mains supply to the heat pump Caution Installation of the heat pump must be done b...

Страница 6: ...comply with the prevailing installation standards Earth the appliance before making any electrical connections For the type and calibre of the protective equipment refer to the chapter Recommended Cab...

Страница 7: ...air work Caution The system should be in Summer or Frost Protection mode rather than switched off to guarantee the follow ing functions Anti blocking of pumps Frost Protection Note Regularly check the...

Страница 8: ...nstallation to the user If maintenance is necessary warn the user of the obliga tion to check the appliance and keep it in good working or der Give all the instruction manuals to the user 1 3 3 User s...

Страница 9: ...mologist immediately Fire prevention meas ures Appropriate extinguishing agents All extinguishing agents can be used Inappropriate extinguishing agents none to our knowledge In the event of fire nearb...

Страница 10: ...es with side protection Skin protection clothing made principally of cotton Industrial hygiene do not drink eat or smoke at the place of work Considerations on dis posal Note Disposal must be done in...

Страница 11: ...ric shock Warning Risk of dangerous situations that may result in minor personal in jury Caution Risk of material damage Note Please note important information See Reference to other manuals or pages...

Страница 12: ...8 16 17 5 39 Nominal water flow rate T 5K m3 hour 0 68 0 99 1 42 1 96 1 96 2 53 2 53 Tab 5 Heating mode outside air temperature 2 C water temperature at the outlet 35 C Performances in accordance wit...

Страница 13: ...4 1 2 3 8 5 8 3 8 5 8 3 8 5 8 3 8 5 8 3 8 5 8 Max pre loaded length m 10 10 10 10 10 10 10 Weight empty Outdoor unit kg 42 42 75 118 118 130 130 Weight empty Indoor module kg 52 52 52 55 55 55 55 1 N...

Страница 14: ...1 52 1 63 Heating water operating limit temperature WTOL C 60 60 60 Electrical power consumption Off mode POFF kW 0 009 0 009 0 009 Thermostat off mode PTO kW 0 049 0 049 0 049 Stand by PSB kW 0 013...

Страница 15: ...temperature Tbiv C 10 10 Degradation coefficient 2 Cdh 1 0 1 0 Seasonal space heating energy efficiency under average conditions s 132 130 Seasonal space heating energy efficiency under colder condit...

Страница 16: ...h and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup Tj 2 If Cdh is not determined by measurement the default degradation coefficient is Cd...

Страница 17: ...ide sensor to adjust the temperature of the heating circuit according to the outside temperature 4 2 Operating principle 4 2 1 Circulation pump Note The benchmark for the most efficient circulators is...

Страница 18: ...e and any error codes 1 Menus Information menu display User menu Installer settings 2 Operating modes Domestic hot water mode Cooling mode only for the reversible versions Shut down Frost Protection m...

Страница 19: ...to shut down the central heating and select an operating mode suited to the situation and the desired comfort level In summer for the sake of comfort it is possible to operate cooling only for the rev...

Страница 20: ...protection Conditions Heating circuit Outside temperature 3 C Heating flow temperature 6 C Protection of the domestic hot wa ter tank Outside temperature 3 C Domestic hot water temperature 4 C 5 Opera...

Страница 21: ...le in euro per kWh and in euro per litre Note The parameters and are available only if 2 Tab 13 Energy cost parameter Parameter Description Adjustment range Increment Factory setting 1 Tariff per kWh...

Страница 22: ...nd keys to modify the operating mode Operating mode Value Screen display Heating and domestic hot water 1 Heating 2 Domestic hot water 3 Cooling and domestic hot water 4 Cooling 5 Shut down Frost Prot...

Страница 23: ...ng and domestic hot water The symbol disappears from the display Back up forcing deactivated 6 2 3 Modifying the room temperature set point 1 Press the key 2 Use the or keys to modify the value Tab 14...

Страница 24: ...tion see Choosing the hybrid operating mode page 21 6 2 5 Modifying the domestic hot water temperature 1 Press the key 2 Use the or keys to modify the value Tab 15 Domestic hot water temperature param...

Страница 25: ...sing the and keys 4 Exit the menu by pressing the key Information menu Parameter Description Unit In heating mode Heating flow set point temperature In domestic hot water mode DHW set point temperatur...

Страница 26: ...available if the estimated electrical energy consumption function is activated 2 Cooling mode must be enabled Tab 17 Examples of energy consumption displays Display example Description Fig 20 Unit 1 k...

Страница 27: ...tion Fig 23 Unit 1000 kWh MW C004235 1 The displayed value is 123000 kWh The unit is 1000 kWh The first digit indicates the scale x 1000 Only the first 3 digits are displayed 6 Settings 7611973 v04 07...

Страница 28: ...top up the water level in the heating system recommended hydraulic pressure between 1 5 and 2 bar or between 0 15 and 0 2 MPa 1 Open the valves on all radiators connected to the heating system 2 Set t...

Страница 29: ...estic hot water tank is connected Automatic venting starts up only if the measured domestic hot water temperature is lower than 25 C Automatic venting takes approximately one minute It is possible to...

Страница 30: ...20 C Bad connection Sensor failure Contact the installer Domestic hot water sen sor error Production of domestic hot water is off Bad connection Sensor failure Contact the installer Flow rate error Th...

Страница 31: ...n domestic hot water temperature Insufficient water supply Check the water pressure in the installation Open the valve The heat pump does not work The heating set point tem perature is too low Increas...

Страница 32: ...9 Decommissioning procedure To decommission the heat pump temporarily or permanently 1 Contact the installer 9 Decommissioning procedure 32 AWHP 2 MIV 3 7611973 v04 07032016...

Страница 33: ...an excellent level of comfort This combination allows you to set the temperature separately for each room However do not install thermostatic radiator valves in the room in which the room thermostat i...

Страница 34: ...g Warning Removal and disposal of the heat pump must be carried out by a qualified professional in accordance with prevailing local and na tional regulations Fig 26 Recycling MW 3000179 03 11 Disposal...

Страница 35: ...le for material damage intangible los ses or physical injury resulting from an installation that does not comply with Legal or regulatory requirements or provisions laid down by the local au thorities...

Страница 36: ...eat pump space heaters AWHP 11 MR 2 AWHP 11 TR 2 AWHP 16 MR 2 AWHP 16 TR 2 Space heating energy efficiency class under average climate conditions A A Rated heat output under average climate conditions...

Страница 37: ...ency class of package under average climate Seasonal space heating energy efficiency of package under average climate Tank rating Collector efficiency in Tank volume in m Collector size in m Seasonal...

Страница 38: ...0 15 0 4 0 15 0 06 0 5 0 05 0 02 0 6 0 02 0 0 7 0 0 1 The intermediate values are calculated by linear interpolation between the two adjacent values 2 Prated is related to the preferential space heat...

Страница 39: ...nological information contained in these technical instructions as well as any drawings and technical de scriptions supplied remain our property and shall not be multiplied without our prior consent i...

Страница 40: ...0 56 130 00 Praha 3 49 0 25 72 9161 0 49 0 25 72 9161 102 info remeha de Via Passatore 12 12010 San Defendente di Cervasca CUNEO 39 0171 857170 39 0171 687875 info duediclima it 420 271 001 627 dediet...

Отзывы: