Instruction manual
Negative Pressure Unit Compact 100.000
Page 17
9.3 Change of filter
Attention:
Contaminated filters have to be changed under all corresponding safety
measures
Filter change only when maschine is switched off
Use only authorised filters
Do not use bonding agents on the machine
Prefilter change:
Remove the locking plates
Gently remove and discard the filter
Insert the new filter
Replace the locking plates
Bag filter change:
The change of the bag filter takes place within the
container
Connect the lock to the service door and enter
in the container through this door.
Open the pressure spring
Remove the bag filter
Insert the new filter
the bags should be perpendicular
Lock pressure spring again
Change of the HEPA filter:
The change of the HEPA filter takes place within the
container .
Connect the lock to the service door and enter
in the container through this door.
Unscrew the nut M10 and remove the
tension bar.
Remove the HEPA filter and discard it
Check and clean the sealing surfaces on the unit
Insert the new HEPA filter
Reattach the tension bar
Pressure spring
Nut M10
Tension bar