Instruction manual
Negative Pressure Unit Compact 100.000
Page 8
5.4 Filter description / Classification
A 3-stage filter combination is integrated in the device
5.4.1 Prefilter:
Filter class pursuant DIN 24185 / EN
779
G3 / EU3
Frame Cardboard
Frame, 47 mm width
Filter medium
Glass fiber
Degree of separation(Am)
85 %
Nominal rated current
5400 m³/h/m²
Nominal velocity in blower stream by
nominal volume
1,5 m/s
Difference of initial pressure
30 Pa
Recommended difference of final
pressure
450 Pa
Temperature / humidity
100 °C / 100 % RF
(relative humidity)
Filter dimensions
610 x 610 x 47 mm
5.4.2 Bag filter:
Filter class pursuant DIN EN 779
F5
Degree of separation (Am)
96 %
Nominal rated current
3400 m³/h
Difference od initial pressure
48 Pa
Recommended difference of final
pressure
250 Pa
Temperature / himidity
55 °C / 100 % RF
(relative humidity)
Filter surface
5,1 m²
Filter dimensions
592 x 592 x 600 mm