background image

 

 

Instruction manual 

 

Negative Pressure Unit Compact 100.000 

 

 

Page 19 

 
 

 

11 Circuit diagram 

 

 

Содержание Compact 100.000

Страница 1: ...Instruction manual Negative pressure unit Compact 100 000 Manufacturer deconta GmbH Im Geer 20 46419 Isselburg Description Type No NPU Compact 100 000 Type 389 Serial No...

Страница 2: ...n the use of the engineered equipment outside of the asbestos removal should be agreed upon beforehand with deconta deconta will help you with pleasure and will take then also the liability by the ext...

Страница 3: ...3 Control cabinet 7 5 4 Filter description 8 5 4 1 Prefilter 8 5 4 2 Bag filter 8 5 4 3 Main filter 9 5 5 Change of filter 10 6 Technical data 11 6 1 Air performance 11 6 2 Performance data 12 6 3 Co...

Страница 4: ...eliability and lifetime of the device We have to point out to you that the non observance of this guide book causes the expiration of your warranty claims Technical changes in images and information t...

Страница 5: ...gally required safety measures during construction and dismantling and maintenance of equipment technology The construction and operation of the device is to be performed only in the operating manual...

Страница 6: ...ide Attach the transport lid at the sucking side and if used filters are installed tape them additionally 4 Scope of delivery at purchase and rent 4 1 Scope of delivery The delivery of the Compact is...

Страница 7: ...An integrated filtering system establishes the conditions that the asbestos concentration in the exhausted air does not exceed max 1000F m The exhausted air is blown in the open air The device is not...

Страница 8: ...m Nominal velocity in blower stream by nominal volume 1 5 m s Difference of initial pressure 30 Pa Recommended difference of final pressure 450 Pa Temperature humidity 100 C 100 RF relative humidity F...

Страница 9: ...dium Glass fiber Sealing mass Polyurethane 2 components glue Seal Polyurethane foamed Filter surface 31 m Filter class S according to DIN 24184 H13 according to DIN EN 1822 Degree of separation 99 95...

Страница 10: ...a signal light Important Use only authorised faultless filter With filter of new condition approximately 950 Pascal are displayed on the gauge Evaluated at 100 capacity We recommend a filter change at...

Страница 11: ...the measuring range end value determined in a multi point measuring method with a calibrated vane anemometer 6 1 Blower performance curve 0 200 400 600 800 1000 1200 1400 1600 1800 2000 5000 10000 150...

Страница 12: ...frequency converters the power peaks are avoided Soft start max 42 A Motor power 2 x 22 KW Filter system 3 steps Pre filter EU3 dimensions 610 x 610 x 47 Bag filter F5 dimensions 592 x 592 x 600 Main...

Страница 13: ...not operate the unit if it is visibly damaged In that case please inform deconta GmbH immediately Connect the container to the sanitation area Seal the container with the sanitation area Ensure that...

Страница 14: ...ied as standard with two engines two engines with electronic control for a control range of each 0 50 000 m h The SRE control developed for the NPU has the principal task to measure out and settle fro...

Страница 15: ...rate Power switch to ON Press key ON OFF IMPORTANT Press and hold the key for about 3 seconds The last saved mode AUTO MANU is automatically set and the fan starts Automatic operating Select the mode...

Страница 16: ...tion the device does not regulate Switch off Press key ON OFF IMPORTANT Press and hold the key for about 3 seconds The device down regulates itself automatically After about 40 seconds switch the main...

Страница 17: ...f the bag filter takes place within the container Connect the lock to the service door and enter in the container through this door Open the pressure spring Remove the bag filter Insert the new filter...

Страница 18: ...a container plant with an effective capacity of 100 000 m h HEPA air filter with protection grid and test certificate pursuant DIN 24184 Class S two pre filter steps consisting of pre filter and bag...

Страница 19: ...Instruction manual Negative Pressure Unit Compact 100 000 Page 19 11 Circuit diagram...

Страница 20: ...Instruction manual Negative Pressure Unit Compact 100 000 Page 20...

Страница 21: ...on instructions First the exhaust air damper must be removed from the negative pressure unit and mounted to the muffler Dismantle the transport lid Transport on the construction site with an approved...

Страница 22: ...Instruction manual Negative Pressure Unit Compact 100 000 Page 22 Crane eyelet Centering aid claws Transport lid Exaust air damper...

Страница 23: ...Instruction manual Negative Pressure Unit Compact 100 000 Page 23 12 1 Sound level measuring Value in dB A Status Engine power 100 free blowing outside...

Страница 24: ...hain in the right socket the device works without remote shutdown 2 Device with remote shutdown Unplug the adapter from the right connector Inser emergency stop switch 3 Connection of multiple devices...

Страница 25: ...unit Type 30 50 40 54 312 313 314 51 38 55 49 23 67 305 329 330 383 389 E107 E108 E110 E105 E106 E109 E112 E111 E113 The design of the units complies EU Machine directive 98 37 EG with the following r...

Отзывы: