AS/400 System Configuration
FORMFEED
CONT
9.3.4Example of Ethernet
AS/400 Configuration
a. Network Attributes
The AS/400 network attributes are configured automatically by the AS/400 system. They
may be viewed and modified (by an authorized user).
Type the command: DSPNETA (to display Network attributes)
Parameter
Value
Current system name:
SYSNAME
Local network ID:
NETID
Local control point name (
see note
):
XXXXXXXX
Default local location (
see note
):
XXXXXXXX
It is recommended to define both the Local Control Point Name and the Default Local
Location Name with the same string.
b. Ethernet Line Description
Type the command: CRTLINETH
Parameter
Value
LIND (Line Description)
ENLIN03
RSRCNAME (Resource names)
LIN03
ADPTADR (Local Adapter address)
400000000000
ETHSTD (Ethernet standard)
*ALL
LINKSPEED (Link speed)
10M
Type CRTLINETH to create AS/400 system line description, WRKCFGSTS *LIN to display
AS/400 system line description, WRKHDWPRD to determine location of AS/400 system line
or hardware.