AS/400 System Configuration
9.2.6AS/400 Configuration for Support of Host-initiated PWS Sessions
To allow LU sessions initiated by the AS/400 with a PWS attached to a 3494 controller (the
AS/400 sends the BIND request to the PWS), the LU and CP names for each PWS must be
configured according to one of the following:
a. The LU name of the PWS is equal to the CP name of the PWS
b. The LU name of the PWS is equal to the CP name of the PWS, plus one additional
character.
For example, if the CP name of the PWS is PWSCPN, the LU name can also be PWSCPN,
or PWSCPN
x
, where
x
is any valid LU name character.
NOTE:
The PWS must initiate the twinaxial, token ring or Ethernet link to the controller
before the latter can forward BIND request to the PWS.
In the AS/400 system that initiated the LU session with the PWS, create an entry in the
remote configuration list to correlate the remote location name and remote control point.
To access the Remote Configuration List Entry screen on the AS/400 system, complete the
following steps:
1. Type
WRKCFGL *APPNRMT
on the command line.
2. Press
Enter
. The screen appears.
3. Type
2
next to the list called QAPPNRMT.
4. Press
Enter
. The Change Configuration List screen appears.
Enter the values for the following configuration parameters:
Remote location
PWS LU name
Remote network ID
PWS network ID
Local location
AS/400 LU name
Remote control point
3494 control point name
Control point network ID
3494 network ID
NOTE:
You must create an AS/400 remote configuration list entry for each PWS that runs
applications that use host-initiate LU sessions.