background image

Troubleshooting

The DecaLED

®

 Controller 3 Mini does nothing. 

Check that the device is connected to the socket via the supplied power cord and that it is switched 

• 

on. 

Check that the red light on the power switch on the backside of the device is turned on. If not, remove the 

• 

device from the socket and change the fuse. This is located under a small lid near the power adapter. 

Check that the Power LED is on. If not, return the device. 

• 

The DecaLED

®

 Controller 3 Mini does not respond to DMX. 

Check that the DMX control LED is on. 

• 

If the control LED is not on, check that DMX is present and/or that the connector is connected correctly. 

• 

Check that the DMX addresses have been set correctly by means of the DecaLED

• 

®

 Setup Tool. 

The connected DecaLED

®

 24V products do not respond. 

Check that the output cables and all connections have been connected correctly. If necessary, remove 

• 

all outputs except 1.

Only a maximum loading capacity of 3A(1A per individual channel) is allowed on a single output and the 

• 

maximum amount of the total load can not exceed 4A distributed over all 2 outputs. 

The DecaLED

®

 Controller 3 Mini cannot be programmed. 

Remove the DMX signal when connecting the DecaLED

• 

®

 Setup Tool. 

Check the DecaLED

• 

®

 Setup Tool and its cables and connections. 

Check the batteries or connect the supplied power supply to the DecaLED

• 

®

 Setup Tool. 

If you cannot find a cause for a defect, we advise you to contact your supplier. Leave repairs to professionals. 

Never try to repair the device yourself, as this could influence your warranty. 

Info: www.lagotronics.com 

 

Содержание 95350246

Страница 1: ... DecaLED Setup Tool Control Mode available in Slave Control mode DMX Mode and Master mode In DMX Mode allows to configure different load output modes as needed consisting of RGB mode Color mode Color Brightness mode and Single mode In Master Mode available in Manual Mode and Auto Mode allows to select 1 10 patterns plus a sequence of 10 patterns with chase speed fade time In Full DMX Control Mode ...

Страница 2: ... objects when cleaning Warranty This product is guaranteed to have no defects as a result of material and manufacturing mistakes for a period of one year after the date of purchase This guarantee only comprises parts that have broken down and repairing costs Repairing will only be done under warranty if it is convincingly proven for example by way of an invoice that the day on which the complaint ...

Страница 3: ...ut connection 3 pin XLR socket Terminal Strip 5 24 4 polar terminal strips 2pcs for connecting DecaLED RGB modules 24V DC Never connect the DMX signal and the Setup Tool to an XLR 3 polar input or output simultaneously This can severely damage your DecaLED Controller 3 Mini for 24V 6 7 To connect an external connected IR EYE sensor 8 To set work modes and relative parameters V DC outputs Built in ...

Страница 4: ...Maximum amount of connected A maximum of 6 channels 2x RGB channels can be controlled separately O 2 Connector configuration The DMX configuration is depicted below The DMX connections consist of one XLR 3 male connector input and one XLR 3 female connector transited output or 3 polar terminal connector DecaLED RGB modules 24V nly a maximum loading capacity of 3A 1A per individual channel is allow...

Страница 5: ...Controller 2 Mini for 12V RGB modules For further information please refer to its accompanying manual 1 1 Slave Control DMX Mode DecaLED Setup Tool Control Mode enables In this mode the Dip Switch 11 2 is flipped to the position and R G B output loading is set by default digit Function Dip Switch ON 1 2 4 5 3 6 Group 1 Group 2 Color R G B Channel 1 6 Group 1 2 Output 1 Output 2 Red Blue MODE 1 RGB...

Страница 6: ...e driver will keep the last received DMX signal information until the driver is switched off or a new and valid DMX signal is sent 4 When in link the Slave will follow the Master all parameter settings of each slave connected unit will be of no effect 1 2 Master Control 1 AUTO mode 2 MANUAL mode AUTO mode and MANUAL mode are for Master Control Relevant functions are as below Preset programs 1 10 p...

Страница 7: ... the different dipswitches that will add up to the value you wish to achieve for example Setting DMX address for 21 Flip switches1 3 5 to the ON position Setting DMX address for 201 Flip switches1 4 7 8 to the ON position Dipswitches Value 1 1 3 4 5 16 21 Dipswitches Value 1 1 4 8 7 64 8 128 201 In this mode the Dip Switch 11 2 is flipped to the position the Dip Switch 10 is to the position And th...

Страница 8: ... Addressing Dip Switch to the OFF position Flip the dip switch 1 3 10 digit Addressing Dip Switch to set up fade time the dip switch 4 6 10 digit Addressing Dip Switch to select chase speed and the dip switch 7 9 10 digit Addressing Dip Switch to select built in 8 patterns Their details can be referred to the below table 0 OFF position 1 ON position 000 100 010 110 001 101 011 111 0 100 1 2 3 14 2...

Страница 9: ... 2S 8 4S 7 8S 6 16S 5 4 3 2 1 32 5S 65S 130S 260S 512S 3 And fade time is available from 0 through 100 total 11levels 10 per level Page 11 4 Effective distance from IR sensor to LED Remote shall be limited within the range of 10m Otherwise it results out of control Pushbuttons Keys Functions RED pushbutton GREEN pushbutton BLUE pushbutton CYAN pushbutton MAGENTApushbutton YELLOW pushbutton WHITE p...

Страница 10: ...orrectly by means of the DecaLED Setup Tool The connected DecaLED 24V products do not respond Check that the output cables and all connections have been connected correctly If necessary remove all outputs except 1 Only a maximum loading capacity of 3A 1A per individual channel is allowed on a single output and the maximum amount of the total load can not exceed 4A distributed over all 2 outputs Th...

Отзывы: