Chapter 6 Description of Operations
PAGE 6-7
6-4-1. Changing Modes in the RUN Mode
In the RUN mode, selection among the five modes can be performed by pressing the [◄] or [►]
switch. Further, in modes other than “Operation View,” the indicated content can be changed by
pressing the [▲] or [▼] switch.
Also when fastening starts, the mode changes
automatically to “Operation View” and at the end of
fastening, the mode changes
to the “Fastening Result Mode.” However, changing of indication and
changing of the mode by the switches cannot be performed during the fastening operation.
Real Time Mode
Operation View
(Change of
Work)
Fastening Result
Mode (COUNT
Indication)
Parameter Setting
Mode
System Setting
Mode
●
Real Time Mode
The currently executed values are indicated in this mode.
The indicated content is changed with
the [▲] or [▼] switch. This mode is indicated immediately
after the activation of the control power.
●
Operation View
The current state of the Unit and the speed state during the fastening operation are indicated in
this mode.
The indication changes to the indication during the fastening operation from the start of fastening
to the end of fastening.
The operation view is indicated when the state of the Unit is changed, such as when an errror
occurs, the STOP signal
is input in the “OFF” state, the BYPASS signal is input in the “ON” state,
etc.
The selected WORK No
. is changed with the [▲] or [▼] switch.
However, this function is disabled when work selection by an external I/O is enabled.
●
Fastening Result Mode
The fastening results are indicated in this mode.
The fastening result content is changed with
the [▲] or [▼] switch.
However, when the fastening result D-No. is [00 (PEAK TORQUE)], the COUNT value [c##] is
indicated.
The result is indicated automatically after the end of fastening.
●
Parameter Setting Mode
The fastening parameters are indicated in this mode.
The indicated set value is changed with
the [▲] or [▼] switch.
●
System Setting Mode
The system parameters are indicated in this mode.
The indicated set value is changed with
the [▲] or [▼] switch.
After activation
of control power
Occurrence of error
or start of fastening
operation
After end of
fastening
S0140185-H
Содержание HFC3000II
Страница 17: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 S0140185 H...
Страница 23: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 S0140185 H...
Страница 28: ...Chapter 2 Specifications PAGE 2 6 Memo S0140185 H...
Страница 29: ...Chapter 3 Part Names PAGE 3 1 Chapter 3 Part Names 3 S0140185 H...
Страница 36: ...Chapter 3 Part Names PAGE 3 8 Memo S0140185 H...
Страница 37: ...Chapter 4 Installation PAGE 4 1 Chapter 4 Installation 4 S0140185 H...
Страница 69: ...Chapter 6 Description of Operations PAGE 6 1 Chapter 6 Description of Operations 6 S0140185 H...
Страница 151: ...Chapter 7 Troubleshooting PAGE 7 1 Chapter 7 Troubleshooting 7 S0140185 H...
Страница 163: ...Chapter 8 Options PAGE 8 1 Chapter 8 Options 8 S0140185 H...
Страница 175: ...Chapter 9 External Interface PAGE 9 1 Chapter 9 External Interface 9 S0140185 H...
Страница 187: ...Chapter 9 External Interface PAGE 9 13 9 3 2 Description of the hardware RUN LED ERR LED CC Link Connector S0140185 H...
Страница 206: ...Chapter 9 External Interface PAGE 9 32 Memo S0140185 H...
Страница 207: ...Chapter 10 Warranty and Servicing PAGE 10 1 Chapter 10 Warranty and Servicing 10 S0140185 H...
Страница 210: ...Chapter 10 Warranty and Servicing PAGE 10 4 Memo S0140185 H...
Страница 211: ...Appendix List of Tool Models Appendix 1 Appendix List of Tool Models Appendix S0140185 H...
Страница 214: ...Appendix List of Tool Models Appendix 4 Memo S0140185 H...
Страница 215: ...Memo S0140185 H...