87
Utility Menu
The Utility menu allows you to edit global system parameters and provides VENU360 system information.
To edit Utility parameters:
1. Press the UTILITY button.
2. Use the SELECT wheel and UP/
DOWN buttons to navigate the
menus and edit parameters.
Utility Parameters
•
SYSTEM INFO
Selecting this option displays important VENU360 system information, such as the currently installed firmware version,
network IP address, and Mac address. You can also view some of this system information via the System Info home
screen. See
‘The Home Screens’ on page 13
for more information on the System Info home screen.
•
ANALOG INPUT/OUTPUT CLIP LEVELS
[INPUTS: +14, +20, +24, +28 dBu / OUTPUTS: +4, +8, +12, +14, +17, +20,
+22 dBu]
Adjust these settings to optimize the analog gain structure between the VENU360 and the connected mixer and
amplifiers or powered speakers. This provides optimal analog signal-to-noise performance and device operation. For
example, if your mixer outputs a maximum level of 28 dBu, you can set the VENU360’s Analog Input Clip Levels to +28
dBu to match. Conversely, if you had your amplifier attenuators maxed out, you could set the Analog Output Clip Levels
to 4 dBu to attenuate the analog output levels and prevent the amplifier from clipping.
WARNING!
The Analog Output Clip Levels will be set for you automatically when selecting your amp models
in the Setup Wizard. To prevent amplifier clipping and loudspeaker damage, use caution when manually changing
these settings. If changing the Analog Output Clip Level settings, it’s advisable to drastically lower your mixer output
level before doing so and then recalibrate the gain structure and Limiter threshold’s before running the system at
performance level.
•
XLR INPUT FORMAT
[XLR 1/XLR 2 FORMAT: ANALOG, AES 1&2/AES 3&4, SAMPLE RATE CONVERSION: OFF,
ON]
This menu allows you to set the input format for the XLR 1 and XLR 2 input jacks. Each jack can be configured for
analog or digital AES connections. Note that 110 ohm balanced cable should be used for AES connections.
When the AES format is selected, sample rate conversion for each XLR jack can also be independently enabled/
disabled in this menu. This allows the VENU360 to accommodate connections from multiple clocks or devices operating
at sample rates other than 48 or 96 kHz. See
‘Configuring XLR Inputs, Master Clock Source, & SRC’ on page
19
for further information on clocking and using sample rate conversion.
Содержание DriveRack VENU 360
Страница 1: ...Owner s Manual ...