54 /87
Here below the complete list of events recognized is indicated:
EVENT
TYPE
CODE
Max Current
ALARM
0001
Max Environment Temp
ALARM
0002
-
[Not used]
0003
[Not used]
Foldback Reflected
WARNING
0004
Reset
INFO
0005
Max Heatsink Temp
ALARM
0006
If Temperature > 68°C
Max Supply Temp
ALARM
0007
-
[Not used]
0008
[Not used]
Interlock Open
WARNING
0009
Power On
INFO
0010
Max Hardware Reflected
ALARM
0011
Fan Warning
WARNING
0012
Frequency Change
INFO
0013
Change to Local
INFO
0014
Change to Remote
INFO
0015
Audio Low
ALARM
0016
Alarm version
Power Low
ALARM
0017
Alarm version
Switch ON
INFO
0018
Switch OFF
INFO
0019
Fault too many Alarms
ALARM
0020
End PLL Unlock
INFO
0021
PLL Unlock
ALARM
0022
Audio Over
ALARM
0023
Alarm version
End Foldback Reflected
INFO
0024
End Hardware Reflected
INFO
0025
End Power Low
INFO
0026
For Alarm version
End Audio Low
INFO
0027
For Alarm version
End Audio Over
INFO
0028
For Alarm version
End Fan Warning
INFO
0029
End Max Heatsink Temp
INFO
0030
Fault Hardware Reflected
ALARM
0031
Too many hardware reflected events
Power Low
WARNING
0032
Warning version
RDS Alarm
ALARM
0033
End RDS Alarm
INFO
0034
Alarms Present
ALARM
0035
At least 1 alarm present
Alarms Absent
INFO
0036
No alarm present
Warnings Present
INFO
0037
At least 1 warning present
Warnings Absent
INFO
0038
No warning present
RF Present
INFO
0039
If Pout > 10% of power set value
RF Absent
INFO
0040
If Pout < 10% of power set value
-
[Not used]
0041
[Not used]
-
[Not used]
0042
[Not used]
Audio Low
WARNING
0043
Warning version
End Audio Low
INFO
0044
For Warning version
End Power Low
INFO
0045
For Warning version
Audio Over
WARNING
0046
Warning version
End Audio Over
INFO
0047
For Warning version
NTP Synchronization
WARNING
0048
End NTP Synchronization
INFO
0049
Warning Reflected
WARNING
0050
End Warning Reflected
INFO
0051
Table 5.23 – Events list