41 /87
5.3.6.9
PILOT TONE PHASE SHIFT
In this menu it is possible adjust the phase of 19KHz pilot tone. This option is available only in
STEREO MPX Internal mode.
Fig. 5.33 – Pilot tone phase adjustment
To change the phase value, press the OK key to enter the program mode (blinking arrow in second
row on the right). Press UP or DOWN keys to increase or decrease the value. Press OK key to
confirm or ESC key to exit routine without saving.
MIN value: -100°
MAX value: +100°
STEP: ±1°
Table 5.11 – Pilot tone phase adjustment permitted values
5.3.6.10
AES-EBU CONTROLS
In these menus it is possible enable/disable the AES-EBU interface. The menus are available in
MONO and STEREO MPX Internal modes.
Fig. 5.34 – AES-EBU interface enable menu
To enable/disable the AES-EBU interface, press the OK key to enter the program mode (blinking
arrow in second row on the right). Press UP or DOWN keys to select ON or OFF. Press OK key to
confirm or ESC key to exit routine without saving.
If the interface is enabled, the internal switch will commutate from analogic Left/Right channels to
digital Left/Right ones but the active channels set in the Operat.Mode menu will not change.
In case of interface enabled the AES-EBU led in the frontal panel will be switched on.