Follow Chapter 4.6 for the electrical connection, with the only caution being
to connect phase L1 of the three-phase system to the terminal marked L on
the DazeBox.
In the case of connecting several single-phase DazeBoxes to the same
three-phase system, we recommend "rotating the phases", i.e. if the first
DazeBox is connected to L1-N, the second is suggested to be connected to
L2-N and so on. This method ensures an even distribution of loads between
the phases in the system. Using this installation method and wanting to use
the DazeBox Power Management, however, some important precautions
must be taken into consideration:

If more than one DazeBox is installed on the system, only one can
activate the Power Management function, any other DazeBoxes
installed downstream of the same meter must be configured to
have fixed power.

If the phases are rotated, the current sensors of the Power
Management must also be connected to the same phase that
supplies the DazeBox. Example: If the L-N terminals of the
single-phase DazeBox are connected to L2 - N (phase 2 - neutral) of
a three-phase system, then the current sensor of the Power
Management must be connected to L2, after the electronic counter
and before each branch of the system.

For the installation of Power Management, see the dedicated manual.

4.10. Release coil connection

The release coil must be installed as described in Section 4.4.

43

Содержание DazeBox C

Страница 1: ...DAZEBOXC Installation Manual...

Страница 2: ...plied with the device to the Customer DazeTechnology shall not be held liable for any damage that may directly or indirectly be caused to persons property or animals due to failure to comply with all...

Страница 3: ...3...

Страница 4: ...3 6 Daze App Matching 16 4 INSTALLATION 17 4 1 Choice of the installation site 17 4 2 Packaging 19 4 3 Transport and preliminary check 19 4 4 Protection and power supply of the charging station 20 4...

Страница 5: ...OF USE 50 6 PRODUCT CARE 52 7 VISUAL SIGNALS 54 7 1 Waiting Power Management status on three phase system 55 7 2 Internal temperature management 56 8 OUT OF SERVICE 57 8 1 Dismantle 57 8 2 Storage 59...

Страница 6: ...overs the installation use and care of the wallbox The most recent and up to date version of this manual can be found on the website The original instructions in this document are in Italian ITA All o...

Страница 7: ...eful documentation See the other documents on the site by framing the QR code DazeBox C Installation Manual EC Declaration of Conformity Drilling template Dynamic Power Management Manual 1 3 Used symb...

Страница 8: ...phase PM Power Management 1 5 Terminology Term Definition Installer External contractor contracted by the owner to carry out technical civil engineering and electrical installation work Owner Legal ow...

Страница 9: ...nd laws Qualified personnel Qualified technical personnel for the design implementation and certification of domestic electrical installations in accordance with local regulations and the energy suppl...

Страница 10: ...nance and decommissioning of the product must only be carried out by qualified and authorised personnel The qualified installation technician must be thoroughly familiar with DazeBox and the procedure...

Страница 11: ...11...

Страница 12: ...of the protective conductor between the vehicle and the mains during charging This control is necessary to ensure that no hazardous voltage can be discharged through accidental contact by unaware per...

Страница 13: ...N Serial number of DazeBox SN Nominal data of DazeBox Product name CE marking The nameplate is located on the rear side of the charging station E in the picture below The data shown may vary depending...

Страница 14: ...ngibile possibile identificare ugualmente il numero seriale SN estraendo il coperchio rimovibile frontale il codice su una piccola etichetta applicata nella parte inferiore dell involucro possibile tr...

Страница 15: ...1 Casing 2 Removable cover 3 Status LED 4 Charging cable with Type 2 connector 5 Connector holder 6 Electrical system with protectors and cables not included 15...

Страница 16: ...IEC 62196 2 EVSE standard IEC 61851 1 IEC 61851 21 CE Marking Yes Warranty 2 years Charging mode Mode 3 Connector cable length Type 2 m 3 5 7 5 7 General specifications Degree of protection IP55 IK08...

Страница 17: ...from photovoltaics Yes optional No User interface Status indicator RGB LED Connectivity Bluetooth WiFi User interface Daze App for Android and iOS External master communication protocol Modbus RTU 3...

Страница 18: ...uctions below The Solar Boost function detects any surplus energy produced not consumed internally by the building and transferred to the grid via the two way meter and dedicates it to recharging the...

Страница 19: ...nd setting up DazeBox via Bluetooth 1 Download the App via Google Play or App Store 2 Add your DazeBox enter the Serial Number and PUK of the wallbox This data can be found on a card inside the DazeBo...

Страница 20: ...facturer or qualified personnel Do not remove safety symbols warning notices cable labels or nameplates 4 1 Choice of the installation site DazeBox is designed to be installed fixed to the wall Theref...

Страница 21: ...sures and rescue routes at the installation location if possible be protected from direct exposure to rain e g to prevent deterioration due to weathering freezing hail damage or similar be protected f...

Страница 22: ...cks The device parts are protected by cardboard packaging After storage and transport to the installation site and immediately before installation prepare the device by taking it out of the box and re...

Страница 23: ...e the earth resistance and cannot start charging if a certain threshold is exceeded Please refer to the technical documentation of the vehicle In any case it is recommended not to exceed 100 for insta...

Страница 24: ...eaker RCD DazeBox must be connected to a mains supply protected by an earth leakage circuit breaker RCD circuit breaker No other electrical circuits may be connected to this earth leakage circuit brea...

Страница 25: ...ease coil The regulations require the installation of a minimum voltage trip in the supply cabinet The tripping device intervenes by actuating the circuit breaker following an opening of the control c...

Страница 26: ...method voltage drop cable length required power or current intensity We recommend using flexible cables to connect DazeBox for ease of wiring especially with large cable cross sections Parameter Spec...

Страница 27: ...ngth 10 mm Cable length coil to DazeBox Cable outer diameter for passage through the DazeBox cable gland diaphragm between 4 5 and 5 5 mm Other important recommendations It is recommended to use a lig...

Страница 28: ...ulating Power Management kWh domestic meter L01 Power cable multi core 6 mm2 conductors L02 2 core cable 2x0 5 mm2 for release coil connection to terminals BRK1 and BRK2 dry contact L03 Integrated cha...

Страница 29: ...29...

Страница 30: ...Wiring diagram of three phase DazeBox 30...

Страница 31: ...either pass through the cable glands at the bottom of the EVSE or through the hole to be opened provided at the back of the DazeBox underlay passage In the latter case open the hole to the desired si...

Страница 32: ...er is provided for DazeBox versions with 5 m and 7 m cable which must be installed at a height of 90 100 cm above the floor A space of at least 20 cm must be left around the charging station at the si...

Страница 33: ...33...

Страница 34: ...pencil using the drilling template A4 sheet supplied Measure the distance to the floor with a tape measure and the perpendicularity of the sheet with a spirit level 2 Drill the holes in the wall usin...

Страница 35: ...4 Remove the DazeBox cover embedded in the casing using the notch at the bottom 5 Place DazeBox on the holes in the wall and secure it using the screws provided 35...

Страница 36: ...the 4 screws shown in the figure with a screwdriver 4 6 DazeBox single phase electrical connection This section explains the electrical connection of the single phase DazeBox to a single phase system...

Страница 37: ...odel once the casing has been opened it looks inside like the drawing in the figure above DazeBox must be connected to a mains supply protected by an earth leakage circuit breaker and a circuit breake...

Страница 38: ...Section 4 4 2 Shorten the connecting cables to the appropriate length avoid leaving too much cable margin Use ferrule tips 3 Connect line L neutral N and earth PE as indicated on the board to the pus...

Страница 39: ...4 7 Three phase DazeBox electrical connection This section explains the electrical connection of the three phase DazeBox to a three phase system If your DazeBox is single phase skip to section 4 6 39...

Страница 40: ...odel once the casing has been opened it looks inside like the drawing in the figure above DazeBox must be connected to a mains supply protected by an earth leakage circuit breaker and a circuit breake...

Страница 41: ...cting cables to the appropriate length avoid leaving too much cable margin Use ferrule tips 3 Connect line 1 L1 line 2 L2 line 3 L3 neutral N and earth conductor PE as indicated on the board to the pu...

Страница 42: ...be connected to the same phase that supplies the DazeBox Example If terminals L1 L2 L3 N of DazeBox are connected to L3 L1 L2 N of the system then the current sensors of the Power Management must be...

Страница 43: ...st be taken into consideration If more than one DazeBox is installed on the system only one can activate the Power Management function any other DazeBoxes installed downstream of the same meter must b...

Страница 44: ...PG on the underside of the wallbox This cable gland has two 5 mm blind holes one for the two core cable from the release coil the other for the Power Management see Dynamic Power Management Manual To...

Страница 45: ...o contacts are interchangeable 4 11 Configuration guide DazeBox installation involves configuring the wallbox according to the desired usage scenario with or without Power Management and Solar Boost a...

Страница 46: ...ed on the top left of the internal circuit board The switches on the selector are individually numbered from 1 to 8 and must be set according to the combinations given in the tables below The tables s...

Страница 47: ...ve Power Management on single phase meter without Solar Boost Table 4 3 Three phase powered DazeBox with active Power Management on three phase meter without Solar Boost Table 4 4 DazeBox powered sing...

Страница 48: ...Single phase 1P Three phase 3P Table 4 1 Single phase fixed power DazeBox Table 4 3 Single phase DazeBox with active PM Table 4 5 Single phase DazeBox with active PM on three phase system Table 4 2 48...

Страница 49: ...drawn by DazeBox A Maximum power absorbed by DazeBox kW 1 2 3 4 5 6 7 8 0 0 0 0 0 0 0 0 6 5 1 5 0 0 0 0 0 0 0 1 7 5 1 7 0 0 0 0 0 0 1 0 8 7 2 0 0 0 0 0 0 0 1 1 10 0 2 3 0 0 0 0 0 1 0 0 10 9 2 5 0 0 0...

Страница 50: ...0 0 1 1 0 13 9 9 6 0 0 0 0 0 1 1 1 15 2 10 5 0 0 0 0 1 0 0 0 17 4 12 0 0 0 0 0 1 0 0 1 19 6 13 6 0 0 0 0 1 0 1 0 21 7 15 1 0 0 0 0 1 0 1 1 23 9 16 6 0 0 0 0 1 1 0 0 26 1 18 1 0 0 0 0 1 1 0 1 28 3 19 6...

Страница 51: ...power of the three phase meter kW 1 2 3 4 5 6 7 8 0 1 1 0 0 0 0 0 26 1 6 0 0 1 1 0 0 0 0 1 30 4 7 0 0 1 1 0 0 0 1 0 32 0 8 0 0 1 1 0 0 0 1 1 32 0 9 0 0 1 1 0 0 1 0 0 32 0 10 0 0 1 1 0 0 1 0 1 32 0 15...

Страница 52: ...Combination switch Maximum current drawn by DazeBox A Contractual power of the single phase meter kW 1 2 3 4 5 6 7 8 0 1 0 1 0 0 0 0 32 0 3 0 0 1 0 1 0 0 0 1 32 0 3 5 0 1 0 1 0 0 1 0 32 0 4 0 0 1 0 1...

Страница 53: ...zes that the decision not to use Power Management is limiting it is enough to switch on an energy hungry appliance such as a washing machine or hairdryer both with a minimum power output of 1 8 kW tog...

Страница 54: ...lation Clean the connection area remove residual material and dirt Check the correct attachment of all terminal connections After following the installation procedure outlined above step by step reass...

Страница 55: ...ged DazeBox the following instructions must be followed in order to avoid the risk of electrocution do not use the device if it is damaged report the presence of the damaged device so that it is not u...

Страница 56: ...the connector to the electric vehicle 4 The car is connected and charging The LED status indicator of the DazeBox is BLUE 5 If the vehicle requests to suspend or interrupt the charging process the LE...

Страница 57: ...57...

Страница 58: ...d be placed neatly in the connector holder in the center of the DazeBox In the case of DazeBoxes with a 5 meter or 7 meter long charging cable wrap the cable around the cable holder provided so that i...

Страница 59: ...zeBox the following instructions must be followed in order to avoid the risk of electrocution do not use the device if it is damaged report the presence of the damaged device so that it is not used by...

Страница 60: ...e outside of the wallbox only after it has been switched off Avoid abrasive sponges solvents or splashing water Inspect the casing and charging cable periodically for possible damage Differential devi...

Страница 61: ...ssion while waiting for sufficient power availability to charge DazeBox can signal this status if the Power Management function has been activated charging will resume automatically when sufficient cu...

Страница 62: ...ts of the connector E06 7 Excessive current consumption detected Charging interrupted vehicle draws more current than permitted E09 10 Detection invalid CP signal Invalid voltage detected on Control P...

Страница 63: ...erature management DazeBox monitors its internal temperature to prevent overheating and protect electronic components When the temperature rises above the recommended thresholds DazeBox limits the cha...

Страница 64: ...allbox must be decommissioned i e taken out of service To dismantle the charging station 1 Follow points 4 and 6 of Chapter 4 5 Assembly 2 In the case of single phase DazeBoxes disconnect the cables f...

Страница 65: ...3 In the case of DazeBox 3P disconnect the cables from terminals L1 L2 L3 N and PE and remove them from the wallbox by pulling them through the cable gland A 65...

Страница 66: ...nting 6 Replace the top cover on the casing 8 2 Storage In case you wish to dismantle and store DazeBox for future use these precautions must be observed in order to maintain its operability clean the...

Страница 67: ...The relative humidity of the air must not exceed 95 and condensation must be avoided 67...

Страница 68: ...ional and national legislation N to drawing Component Waste type 1 Charging Cable RAEE 2 LED PCB RAEE 3 DZCOB PCBS RAEE 4 Battery Alkaline batteries 5 Spacers and screws Metal waste Packaging material...

Страница 69: ...69...

Страница 70: ...NOTES 70...

Страница 71: ...71...

Страница 72: ...72...

Страница 73: ...CUSTOMER SERVICE PLEASE CALL 035 1983 1355 From Monday to Friday 8 30 13 00 14 00 18 00 FOLLOW US ON...

Отзывы: