10
Function
Code
Name
Setting Range
Factory
Setting
Description
All Lower
Limit
b01.06
0.00~
10.00V
1.00V •
Lower limit use to transducer zero
setting
•
Higher limit use to accordant
display and transducer pressure
•
When display smaller than
gauge increase higher limit.
When display is greater than
gauge, decrease higher limit.
•
When analog input is interfered,
prolong filtering time so as to
increase the ability of anti-
interference but decreases the
sensitivity.
•
Corresponding relationship of
transducer parameter setting:
Corresponding
Setting of AI1
Lower Limit
b01.07
-100~100%
0.0%
Al1 Higher
b01.08
0.0~10.0V
5.00V
b01.09
Corresponding
Setting of Al1
Higher Limit
-100~100% 100%
b01.10
Al1 Filtering
Time
0.00-10.00s 0.10s
b01.11
AI2 Lower
Limit
0.00-10.00V
Corresponding
Pressure Setting
Lower
Limit
Upper
Limit
Max Range of
Transducer
0
1.00V
Figure 5.1.1 Transducer
Parameters
b01.12
Corresponding
Setting of AI2
Lower Limit
-100~100%
0.0%
b01.13
AI2 Lower
Limit
0.00-10.00V 5.00V
b01.14
Corresponding
Setting of AI2
Higher Limit
-100~100% 100%
b01.15
AI2 Filtering
Time
0.00~10.00s 0.10s
0:Invalid 1:Valid
b01.16
0~1
0
Restart After
Power-on
0:Synchronous 1:Master-Slave
b01.17
0~1
1
Control Mode
0:Keypad 1:Reserved
b02.00
0~1
0
PID Source
Selection
0:A11 1:Reserved
b02.01
0~1
0
PID Feedback
Source
Selection