Plug the test leads into input jacks.
Rotate the switch to “
Ohm
” mode.
Choose the highest range (
x1K)
when the value to
be measured is unknown.
Connect the test lead to the target, polarity can be
ignored.
For Resistance read of the scale (Green) as
described in
Reading the Scale.
For Continuity test, turn the rotary switch to “
”.
Connect the leads to the circuit. If the circuit is well
connected, the Meter will buzz to indicate good
continuity.
NOTE:
When switching between resistance mode and other
modes, always calibrate the needle to zero before
making measurement.
Extension Cords Continuity Test
Unplug the cord from two sides. Set the rotary switch to
the ohm x1K position. Touch one of the test leads to one
of the metal prong ends of the cord, insert the other test
lead in either one of the receptacle slots on the other
end of the cord. Make sure the test lead is making
contact with the slot. Test both slots with the test lead,
making sure in both cases that the leads are well