5
The level value is not
accurate with the actual
level of waste in the
trash bin.
5.1
The transducer is covered by a thin
layer of dust or particles.
Clean the transducer surface with a
soft detergent and clean water.
5.2
The A & B parameters are wrong or
not written to the sensor yet.
Check the calculation of A&B again
and make sure they are written
successfully to the sensor.
6
HW_Error = 1
6.1
The lost connection between the
transducer and the main PCB.
Open the sensor housing and check
the internal wire and connector from
the transducer to the wireless PCB.
6.2
The transducer got a problem.
Please consult the manufacturer for
a warranty or replacement.
There are no moving parts or consumed parts in the ULA ultrasonic level sensor. Therefore there is no need to do
maintenance.
However, depending on the installation environment, the transducer must be checked and cleaned periodically
for accurate measurement.
This ULA Ultrasonic level sensor has the default configuration. The user can change the configuration on the wireless
transmitter so that the complete sensor (tran wireless) delivers the proper output value. Below are some
configuration parameters that store in the flash memory of the wireless transmitter.
Description
Unit
Default
Format Property
Comment
CONSTANT_A
1
Float
R/W
Constant a for scaling measured value
CONSTANT_B
0
Float
R/W
Constant b for scaling measured value
HIGH_CUT
1E+09
Float
R/W
High cut value for scaled value
LOW_CUT
-1E+09
Float
R/W
Low cut value for scaled value
SENSOR_BOOT_TIME
mS
500
Uint32
R/W
Boot time of sensor/input, in ms
NUM_OF_SAMPLES
30
Uint16
R/W
Number of samples for filtering function
END.
7. Maintenance of the ULA Ultrasonic Level Sensor
8. Default configuration
Содержание Lidar People Counter
Страница 2: ...Daviteq Optical Sensing Technologies...
Страница 8: ...Daviteq Radar Sensing Technologies...
Страница 9: ...Daviteq Gas Detection Technologies...
Страница 27: ......
Страница 34: ......
Страница 38: ...C m u n i M12 v o c m bi n Si t ch t k t n i M12...
Страница 43: ...Daviteq Electrical Sensing Technologies...
Страница 51: ...Daviteq Ultrasonic Level Distance Measuring Technologies...
Страница 57: ...Thermal mass flow Pitot tube Orifice plate Daviteq Air Gas Flow Measurement Technologies...
Страница 64: ...Figure 12 Adjust the orientation of the probe 5 7 Attach the Wireless Transmitter to the probe...
Страница 67: ...Daviteq Inertial Measurement Technologies...
Страница 80: ...Daviteq Pressure Measurement Technologies...
Страница 87: ...Tel 84 28 6268 2523 4 ext 122 Email info daviteq com www daviteq com...
Страница 88: ...Daviteq Soil Measurement Sensors...