19532P-76 (09-15)
of 22
13
5. Power Cable
Parts/Tools Required
C95-20PW Power Cable (40919G-01)
2-Amp Circuit Breaker location on ship or David Clark 2-Amp Fuse kit (40688G-47)
Soldering iron or crimp terminals
Wire cutters
Tape Measure
Wire strippers
Power Cable label
1
2
+13.8 V.D.C
GND
D.C.C.I. Cable
09815P-20 HA000
or Equivalent
Sw13.8 V.D.C
+13.8 V.D.C Return
Measure and Strip
Jacket 2-1/2” from
Cable End
RED
BLK
C95-20PW
Power Cable
P/N 40919G-01
To Master Station
Main P.C. Board J5
Figure 7
Procedure
Determine the location of the 11-30VDC source and Ground pick-off points
o
Preferably a 2-Amp circuit breaker
o
Connection method (solder, screw terminals, lugs, etc)
If only a higher-amperage circuit breaker is available, it may be used, but the David Clark 2-Amp
Fuse Kit (40688G-47) must also be used.
Determine the path of the cable between the power source and the Master Station. The cable
should be routed using under-deck conduits and be as far as possible from radio antenna coax
cables and anywhere water may collect.
Measure the length of cable necessary, adding 3 ft as a service loop.
If necessary, trim the length of the cable to the length you just determined in the previous step.
Route the cable. Use grommets each time the cable is passed through a wall or surface. Use
wire ties where necessary.
Feed the Master Station end of the cable through the
F1
cable fitting. See
Appendix A
.
Pull cable through fitting approximately 2-3 ft to allow room for termination.
Using the provided cable labels, label the cable once it is through the fitting and inside the
Master Station.