19532P-76 (09-15)
of 22
15
6. Master Station Internal Connections
Parts/Tools Required
Blue AMP connectors (One for each Radio cable and each System cable)
Yellow AMP connector (One required for Power cable)
White AMP connectors (One for each Remote PTT cable)
AMP tool 59803-1 for blue & white connectors
AMP tool 59804-1 for yellow connectors
Screwdriver (for top cover screws)
Waterproof sealant/caulking
Procedure
Affixing AMP Connectors to Cables
Using the chart in
Table 2
(next page), affix the correct connector to each cable.
o
Use the
Correct
AMP Tool
for each connector.
o
See
Appendix C
for proper wiring and use of AMP tools.
Place the connector on a flat surface or suitable support to prevent rocking when inserting the
wires.
Position wire over the contact in the AMP connector. Make sure the end of the wire does not
extend over the shoulder of the connector. Start the wire into contact with finger.
Place appropriate tool on wire over contact so that the center line of the tool matches the
contact. The tool must be positioned as shown in
Appendix C
.
Holding the tool handle perpendicular to the contact, apply a constant, direct pressure until the
wire is terminated with the contact. Exert pressure in such a manner as to avoid contact
damage.
Ensure that a good connection is made to each terminal on the connectors. The wires should
look just like the picture. Trim cable and reinstall any connectors that are not done properly.
Содержание 9500 SERIES
Страница 2: ......
Страница 4: ......
Страница 10: ...19532P 76 09 15 of 22 6 Figure 2 Mounting the Master Station ...
Страница 11: ...19532P 76 09 15 of 22 7 ...
Страница 12: ...19532P 76 09 15 blank of 22 8 ...