59
4.3.4.Metering (Analog) Inputs
The Metering inputs are used to process and measure analog signals. They are bipolar, differential inputs with common-
mode rejection of up to 80V. They can be configured for signal detection (pseudo RMS) an also for 4-20mA modes.
Please see Section 4.3.1 for details about the generic
Main
screen,
Description
screen and
Vocal Description
screen.
1 –
ID
ID of the selected input. Select from the drop-down menu.
2 –
I/O DESCRIPTION RETRIEVAL
Click to retrieve and display the current normal description of that ID. Normally hidden to minimize data transfers
on low speed or high fee data connections.
3 –