background image

~ 3 ~

Power Connection

The pump motor is fitted with an earthed three pin plug & lead.

The installer is responsible for the correct connection of the electrical supply to the pump motor.

• 

Make sure the supply voltage and frequency is the same as the nameplate.

• 

Make sure that there is a sound earth connection available.

In accordance with AS/NZS 60335.2.41 we are obliged to inform you that this pump is not to be used by children or infirm 

persons and must not be used as a toy by children.

EARTH CONNECTION

The pump power lead includes an earth pin on the plug, which MUST be correctly connected to a suitable earth 

on the electrical supply.

POWER CONNECTION

Connect lead to power supply designated on pump label.  Do not use long extension leads as they cause 

substantial voltage drop, poor pump performance and may cause motor overload.

Electrical Power Surge Protection

An electrical power surge or spike can travel on the supply lines and cause serious damage to your electrical equipment.  

The controller fitted to this pump has a metal oxide varistor (MOV) fitted to help protect it’s circuit.  This MOV is a 

“sacrificial” device, meaning that it effectively gradually destroys itself every time it takes a surge.  The MOV is not a 

lightning arrestor and may not protect the controller if lightning or a very powerful surge hits the pump unit.

If the installation is subject to electrical power surges or lightning we strongly recommend the use of a suitable surge 

protection device on ALL electrical equipment.

Pipe Connections

For best performance use P.V.C. or polythene pipes at least the same diameter as the pumps inlet and delivery outlet 

openings.  Larger diameter pipe may be used to minimise resistance to flow when pumping longer distances.

Use unions as pipe connections to enable easy removal and servicing.  Use sufficient tape to ensure airtight seal and 

hand tighten only.  To prevent strain on pump threads always support heavy inlet and outlet pipes.  If there is a likelihood 

the water supply may contain solid particles such as pieces of plant or vegetable matter, a suction strainer should be 

installed before the pump to avoid blocking of the pump.  Lay suction pipe at a constant gradient to avoid air pockets 

which reduce pump efficiency.
It is possible with some specific garden hose connections, to block off the discharge of the pressure controller, if the 

garden hose adapter is fitted directly onto the controller. If user intends to use this specific fitting directly onto the 

controller, Davey recommends using a threaded spacer (available from most irrigation and hardware stores). This will 

ensure the tap fitting’s gasket doesn’t block the discharge of the controller.

Garden hose adapter

Threaded spacer

 

NOTE - Suction leaks are the largest cause of poor pump performance and are difficult to detect.  Ensure all 

connections are completely sealed USING THREAD TAPE ONLY.

Содержание SJ35-04

Страница 1: ...these instructions on to the operator of this equipment Manual Pressure Pump Model SJ35 04 Automatic Water Pressure System Models SJ35 04PC SJ60 08PC Garden Series Jet Pumps Installation Operating In...

Страница 2: ...P M 2 Suction inlet SJ35 04PC 1 BSP F SJ60 08PC 11 4 BSP F 3 Pump body 4 Motor 5 Priming port and plug 6 Drain port and plug 7 Pressure controller Do not use this pump to pump flammable fluids such as...

Страница 3: ...e installation is subject to electrical power surges or lightning we strongly recommend the use of a suitable surge protection device on ALL electrical equipment Pipe Connections For best performance...

Страница 4: ...st not exceed 45o C or damage caused will not be covered by guarantee Connection of Mains Scheme or Town Water Supply to either Suction or Discharge of Pump Most Water Supply Authorities have strict r...

Страница 5: ...e a delay of a few seconds before the pump starts and the yellow Pump On led will light up 4 Prime should establish almost immediately and a strong flow of water should be evident from the outlet Allo...

Страница 6: ...6 Check valve installed in wrong direction 7 Suction lift too high 8 Leaking air bleed screw 9 Blocked jet or venturi 10 Blocked impeller PUMP STOPS BUT RESTARTS QUICKLY NO FLOW DEMAND AUTO MODELS ON...

Страница 7: ...7 NOTES...