Davey SJ35-04 Скачать руководство пользователя страница 4

~ 4 ~

Installations with a Suction Lift

Installations with a suction lift require a good quality foot valve to avoid loss of prime.

Installations with Flooded Suction

Installations with flooded suction require a gate valve so water supply can be turned off for pump removal and servicing.

WARNING

DO NOT RUN DRY.

DO NOT RUN WITHOUT WATER.

DO NOT PUMP WATER CONTAINING ABRASIVE MATERIALS.

Abrasive Materials

The pumping of abrasive materials will cause damage to the pump which will then not be covered by the guarantee.

Water temperature in pump must not exceed 45

o

C, or damage caused will not be covered by guarantee.

Connection of Mains Scheme or Town Water Supply to either Suction or 

Discharge of Pump

Most Water Supply Authorities have strict regulations regarding 

direct connection of pumps to mains water supplies. In most 

cases an isolating tank is required between mains supply and 

pump.  This is also the recommend method for this pump.  

Directly applied mains pressure can exceed pump operating 

pressure and damage pump.

Davey Products Pty Ltd can not accept

responsibility for loss or damage resulting from

incorrect or unauthorised installations.

 

NOTE - If connecting your SJ Jet Pump direct to mains water, the casing pressure (maximum outlet pressure) 

must not exceed 600kPa (6bar/87psi).

Содержание SJ35-04

Страница 1: ...these instructions on to the operator of this equipment Manual Pressure Pump Model SJ35 04 Automatic Water Pressure System Models SJ35 04PC SJ60 08PC Garden Series Jet Pumps Installation Operating In...

Страница 2: ...P M 2 Suction inlet SJ35 04PC 1 BSP F SJ60 08PC 11 4 BSP F 3 Pump body 4 Motor 5 Priming port and plug 6 Drain port and plug 7 Pressure controller Do not use this pump to pump flammable fluids such as...

Страница 3: ...e installation is subject to electrical power surges or lightning we strongly recommend the use of a suitable surge protection device on ALL electrical equipment Pipe Connections For best performance...

Страница 4: ...st not exceed 45o C or damage caused will not be covered by guarantee Connection of Mains Scheme or Town Water Supply to either Suction or Discharge of Pump Most Water Supply Authorities have strict r...

Страница 5: ...e a delay of a few seconds before the pump starts and the yellow Pump On led will light up 4 Prime should establish almost immediately and a strong flow of water should be evident from the outlet Allo...

Страница 6: ...6 Check valve installed in wrong direction 7 Suction lift too high 8 Leaking air bleed screw 9 Blocked jet or venturi 10 Blocked impeller PUMP STOPS BUT RESTARTS QUICKLY NO FLOW DEMAND AUTO MODELS ON...

Страница 7: ...7 NOTES...

Страница 8: ...ts of similar quality grade and composition where an identical part or component is not available Goods presented for repair may be replaced by refurbished goods of the same type rather than being rep...

Отзывы: